5.4.4

Commissioning with vapor

Pressure transmitter
Stabilizing valve
,
Differential pressure valves
Differential pressure lines
Shut-off valves
Figure 5-2
Measuring steam
Condition
All valves are closed.
Procedure
WARNING
Hot vapor
Danger of injury or damage to device.
If the shut-off valves
the transmitter
can be damaged by the flow of vapor.
● Follow the specified procedure for commissioning.
WARNING
Hot vapor
Danger of injury.
You can briefly open the drain valves
● Only open the drain valves
To commission the transmitter for vapor, proceed as follows:
1. Open both the shut-off valves
2. Open the stabilizing valve
3. Wait until the steam in the differential pressure lines
30
and the differential pressure valve
to clean the line. Hot vapor can escape in the process.
briefly, and close them again before vapor escapes.
at the pressure tapping point.
.
Drain valves
Condensate pots
Differential pressure transducer/Orifice plate
Insulation
are both open and the stabilizing valve
and in the equalizing vessels
SITRANS P DS III (7MF4.33.. 7MF4.34.. 7MF4.35..)
is then opened,
has condensed.