Foam Resins With 245 Fa Blowing Agents; Changing Materials - Graco GX-8 Operation, Parts, Service, Repair

For use with non-flammable polyurethane foams, two-component coating systems (polyureas), and some two-component epoxy systems. for professional use only. not for use in explosive atmospheres. 3500 psi (24 mpa, 240 bar) maximum working pressure 125 psi (9
Table of Contents

Advertisement

Foam Resins with 245 fa
Blowing Agents
Some foam blowing agents will froth at temperatures
above 90°F (33°C) when not under pressure, especially
if agitated. To reduce frothing, minimize preheating in a
circulation system.

Changing Materials

Changing the material types used in your equipment
requires special attention to avoid equipment damage
and downtime.
When changing materials, flush the equipment
multiple times to ensure it is thoroughly clean.
Always clean the fluid inlet strainers after flushing.
Check with your material manufacturer for chemi-
cal compatibility.
When changing between epoxies and urethanes
or polyureas, disassemble and clean all fluid com-
ponents and change hoses. Epoxies often have
amines on the B (hardener) side. Polyureas often
have amines on the B (resin) side.
311338N
NOTICE
Important Two-Component Material Information
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-8p

Table of Contents