Supply voltage
230 V a.c. +10/-15 %. 2.5 VA, 50/60 Hz
Pt 1000 or
Sensors 3 pcs o
PTC 1000 or
either
NTC-M2020 (5000 ohm / 25°C)
Measuring range -60 to +99°C
Controller
Accuracy
Pt 1000 sensor
Display
LED, 3-digits
External display
EKA 163A
Signal from contact functions
Requirements to contacts: Gold plating
Digital inputs
Cable length must be max. 15 m
Use auxiliary relays when the cable is longer
Electrical con-
Max.1,5 mm
2
multi-core cable
nection cable
DO1.
Refrigeration
DO2. Defrost
Relays*
DO3. Fan
DO4. Alarm
0 to +55°C, During operations
-40 to +70°C, During transport
Environments
20 - 80% Rh, not condensed
No shock in uence / vibrations
IP 65 from front.
Density
Buttons and packing are imbedded in the front.
Escapement
reserve for the
4 hours
clock
EU Low Voltage Directive and EMC demands re CE-
marking complied with
Approvals
LVD tested acc. EN 60730-1 and EN 60730-2-9, A1, A2
EMC tested acc. EN61000-6-3 and EN 61000-6-2
* DO1 and DO2 are 16 A relays. The mentioned 8 A can be increased up to 10 A, when the
ambient temperature is kept below 50°C. DO3 and DO4 are 8 A relays. Max. load must be kept.
** Gold plating ensures make function with small contact loads
*** UL-approval based on 30000 couplings.
Capacitive load
The relays cannot be used for the direct connection of capacitive loads such as
LEDs and on/o control of EC motors.
All loads with a switch mode power supply must be connected with a suitable
contactor or similar.
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alternations can be made without subsequential changes being necessary in speci cations already agreed.
All trademarks in this material are property of the respecitve companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
24
±1 K below -35°C
±0.5 K between -35 to +25°C
±1 K above +25°C
±0.3 K at 0°C
±0.005 K per grad
CE
UL ***
(250 V a.c.)
(240 V a.c.)
10 A Resistive
8 (6) A
5FLA, 30LRA
10 A Resistive
8 (6) A
5FLA, 30LRA
6 A Resistive
3FLA, 18LRA
6 (3) A
131 VA Pilot
duty
4 A Resistive
4 (1) A
131 VA Pilot
Min. 100 mA**
duty
Manual
RS8EP502
©
Danfoss
12-2015
53