Electrical / Refrigeration; Merchandiser Electrical Data; Field Wiring; Electrical Connections - Hussmann DDSS-4MC Installation & Operation Manual

Medium temperature self contained open vertical merchandisers
Table of Contents

Advertisement

P/N 0515957_M

MERCHANDISER ELECTRICAL DATA

Refer to merchandiser serial plate for electrical
information.

FIELD WIRING

Field wiring must be sized for component
amperes stamped on the serial plate. Actual
ampere draw may be less than specified.
ALWAYS CHECK THE SERIAL PLATE FOR
COMPONENT AMPERES

ELECTRICAL CONNECTIONS

All wiring must be in compliance with NEC
and local codes. All electrical connections (for
remote models) are to be made in the electrical
Handy Box located behind the removable base
panel at the left end of the merchandiser when
facing the discharge honeycomb.

ELECTRICAL OUTLET

Before the merchandiser is connected to any
wall circuit, use a voltmeter to check that the
outlet is at 100% of the rated voltage. The wall
circuit must be dedicated for the merchandiser.
Failure to do so voids the warranty. Do not use
an extension cord. Never plug in more than one
merchandiser per electrical circuit.
• Always use a dedicated circuit with the
amperage stated on the unit.
• Plug into an outlet designed for the plug.
• Do not overload the circuit
• Do not use long or thin extension cords.
Never use adapters.
• If in doubt, call an electrician.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.

ELECTRICAL / REFRIGERATION

— LOCK OUT / TAG OUT —
To avoid serious injury or death from electri-
cal shock, always disconnect the electrical
power at the main disconnect when servicing
or replacing any electrical component. This
includes, but is not limited to, such items as
doors, lights, fans, heaters, and thermostats.
Self-contained models have
factory-installed power cords
attached at the electrical box.
NEMA 6-20R
Receptacle
DDSS-4MC
REFRIGERATION
(Self Contained Models)
Each self contained model is equipped with
its own condensing unit and control panel
located beneath the display area. The correct
type of refrigerant will be stamped on each
merchandiser's serial plate. The merchan-
diser refrigeration piping is leak tested. The
unit is charged with refrigerant, and shipped
from the factory with all service valves open.
Risk of Electric Shock. If cord or plug
becomes damaged, replace only with
a cord and plug of the same type.
Merchandiser must be grounded.
Do not remove the power supply cord ground.
DDSS Open Vertical Merchandisers
2-1