Setup - Graco 960P Instruction Manual

Turbine spray guns 50 psi (0.35 mpa, 3.5 bar) maximum inlet fluid pressure / 100 psi (0.7 mpa, 7 bar) maximum inlet air pressure
Table of Contents

Advertisement

Connect Fluid and Air Supply
NOTES:
D The HVLP Cart/Compressor provides the air supply
for remote pressure pot.
D The circled letters in Fig. 1 indicate hose line
connections.
1. Connect gun air supply hose (A) between turbine
air outlet (B) and gun air inlet (C). DO NOT use
wrench to tighten connections; hand tighten only.
See Fig. 1.
For GTS–4900:
The turbine uses quick connector at outlet (B). A
wrench is not required for hose connection.
2. If using a spray gun cup (D):
Connect cup to gun fluid inlet (E).
If using accessory remote pressure pots (F):
Connect fluid supply hose (G) between remote
pressure pot fluid outlet (H) and gun fluid inlet (E).
E
G
Y
remote pressure pot
setup for spray gun
G
H
Y
F
2-quart remote pressure pot
Fig. 1
4
308336
C
A
B
X
X
Z
K
J
Z

Setup

3. Connect pressure pot air hose (J) between pres-
sure pot air regulator inlet (K) and the cart com-
pressor air outlet.
Install Fluid Set
Complete spray guns are available with #1, #2, #3, #4,
or #5 fluid sets. To install other fluid sets, perform the
following steps. See Fig. 2.
1. Remove air cap retaining ring (29). Discard pack-
aging (not shown). Remove detente plate and
spring (25).
2. Remove fluid regulator assembly (20, 21, 22) and
spring (23) from back of gun.
L
1
2
/
D
cup-over option
E
D
X
cup setup for spray gun
J
K
H
Z
Y
F
-gallon remote pressure pot
2
C
A
G
04958B