12. Sensor Values

Discharge Line
Temperature Sensor Resistance
Resistance
°F
(kOhms)
-40
2889.60
-31
2087.22
-22
1522.20
-13
1121.44
-4
834.72
5
627.28
14
475.74
23
363.99
32
280.82
41
218.41
50
171.17
59
135.14
68
107.44
77
86.00
86
69.28
95
56.16
104
45.81
113
37.58
122
30.99
131
25.68
140
21.40
149
17.91
158
15.07
167
12.73
176
10.79
185
9.20
194
7.87
203
6.77
212
5.85
221
5.09
230
4.45
239
3.87
248
3.35
257
2.92
266
2.58
275
2.28
284
2.02
293
1.80
302
1.59
311
1.39
320
1.25
329
1.12
338
1.01
347
0.92
356
0.83
© 2016 Emerson Climate Technologies, Inc.
Temperature Sensor Resistance
(Excludes DLT)
Resistance
°F
(kOhms)
-55
302.2
-50
254.9
-45
221.7
-40
188.5
-35
160.2
-30
140.4
-25
120.2
-20
105.7
-15
90.8
-10
80.3
-5
69.4
0
61.5
5
53.4
10
46.5
15
41.5
20
36.3
25
32.4
30
28.5
35
25.6
40
22.5
45
20.3
50
18.0
55
15.9
60
14.4
65
12.8
70
11.6
75
10.4
80
9.46
85
8.47
31
AE5-1412 R1
Resistance
°F
(kOhms)
90
7.73
95
6.94
100
6.25
105
5.73
110
5.17
115
4.75
120
4.30
125
3.96
130
3.59
135
3.32
140
3.02
145
2.75
150
2.55
155
2.33
160
2.16
165
1.98
170
1.84
175
1.69
180
1.58
185
1.45
190
1.34
195
1.25
200
1.15
205
1.08
210
0.998
215
0.937
220
0.868
225
0.816
230
0.758