C. GEARBOX INSTALLATION
1.
Place the gear box in position from the rear of
the machine. Fasten the three bolts through the
gear box to the rear of the barrel.
2.
Fasten the gearbox to the mounting bracket using
the two bolts.
3.
Mount the pulley on the gear box shaft and align
with the motor pulley, then tighten the allen head
screws.
4.
Install the belt.
5.
Press fi rmly on the belt.
6.
When the tension is properly adjusted, the belt
will depress the approximate width of the belt with
the pressure of a fi nger.
7.
If an adjustment is necessary, loosen the four
motor plate retaining nuts, adjust belt tension
then retighten the four nuts.
6.6
CONDENSER FAN MOTOR (AIR-
COOLED ONLY)
A. FAN MOTOR REPLACEMENT
1.
Disconnect machine from electrical supply before
removing any panels for servicing.
WARNING
Hazardous voltage
The Main Freezer Power switch must be placed in
the OFF position when disassembling for servicing.
The machine must be disconnected from electrical
supply before removing any access panel. Failure
to disconnect power before servicing could result
in death or serious injury.
2.
Remove a side panel and the header panel.
3.
Trace and disconnect the black and white wires
on the T1 and T2 terminals on the compressor
contactor.
4.
Loosen set screw on fan blade.
5.
Remove the three bolts from the fan motor
mounting plate and remove the motor.
B. FAN MOTOR INSTALLATION
1.
Attach motor to the mounting plate with the three
bolts.
2.
Place fan blade on motor shaft and tighten set
screw.
3.
Ensure purple wire is terminated.
4.
Ensure red wire is terminated with blue wire.
5.
Route white and black wires through the front
panel to the compressor contactor.
6.
Connect black wire to the T1 terminal.
7.
Connect white wire to the T2 terminal.
6.7

CAB CONDENSER FAN MOTOR

A. FAN MOTOR REPLACEMENT
1.
Shut the machine down and remove mix from the
freezing barrel and cab.
2.
Disconnect machine from electrical supply.
3.
Remove the mix containers and sliding drawer
from the cab.
4.
Disconnect the evaporator drain tube and remove
the two thumb screws on the evaporator cover.
Pull the cover off and set aside.
5.
Remove the tubes from the mix transfer line and
air line.
6.
Remove the four screws on the fan shroud. The
screws are attached to the cab wall.
7.
Pull thermistor out of the clip and thread it up
through the hole in the fan shroud.
8.
Remove the fan shroud by tilting forward and
pulling down (Refer to Figure 6-7).
Figure 6-7 Cab Fan Shroud
9.
Remove the two fan bracket screws and
disconnect wires.
10.
Connect the wires to the new fan motor.
11.
Attach the two screws to the fan motor bracket.
12.
Tilt the fan shroud and move it into place.
13.
Thread thermistor through hole in fan shroud and
attach it to the clip.
14.
Install fan shroud into cab with the four screws.
15.
Install evaporator cover with the two thumb screws.
16.
Install all tubes and replace sliding drawer and
mix containers.
6.8

SWITCHES

A. SPIGOT SWITCH
The spigot switch is a normally closed, held open switch.
When a spigot is pulled, the spigot switch sends a signal
to the IntelliTec control to start the auger drive and refrig-
eration system. This signal moves the control to "Serve
Mode", or if it already is in "Serve Mode", it resets the
cycle count. After serving product, the IntelliTec continues
a freezing cycle until the product reaches consistency.