Remove the spigots through the bottom of the
front door. Remove all o-rings from spigots and
air bleed valve.
B. Disassembly Of Auger
1.
Remove the front auger support by pulling it
straight out of the machine barrel.
2.
Remove the plastic bearing from the front auger
support.
Figure 3-4 Front Door Disassembly
3.
Remove the auger by pulling slowly and rotating
out of the machine barrel. As the auger is
withdrawn, remove each plastic fl ight and spring
from the auger (Fig. 3-5). Be careful not to scratch
inside of machine barrel when removing fl ights or
auger. Remove the spring from each auger fl ight.
4.
Keep the rear of the auger tipped up once it is
clear of the machine barrel.
5.
Wipe spline lubricant off of the hex end of auger
with a paper towel. Remove the rear seal assembly
(Fig. 3-6).
Figure 3-5 Auger Flight Removal

3.5 CLEANING DISASSEMBLED PARTS

Disassembled machine parts require complete cleaning,
sanitizing and air drying before assembling. Local and state
health codes will dictate the procedure required. Some
state health codes require a four sink process (pre-wash,
wash, rinse, sanitize, air dry), while others require a three
sink process (without the pre-wash step). The following
procedures are a general guideline only. Consult your
local and state health codes for procedures required in
your location.
Valve Stem
Air Bleed
Valve
A.
B.
C.
D.
F.

3.6 SANITIZING MACHINE PARTS

A.
B.
17
From Inside Insert
Figure 3-6 Rear Seal Removal
To clean the machine parts disassemble all
parts. (Refer to Section 3.4 for the disassembly
of machine parts.)
Place all front door and auger parts in clean 90° to
110°F (32°C to 43°C) water and wash thoroughly
(four sink procedure only).
Place all parts in 90° to 110°F (32°C to 43°C) ,
mild detergent water and wash thoroughly.
Rinse all parts with clean 90° to 110°F (32°C to
43°C) water.
Sanitize all machine parts following procedures
outlined below.
Use a sanitizer mixed according to manufacturer's
instructions to provide a 100 parts per million
strength solution. Mix sanitizer in quantities of no
less than 2 gallons of 90° to 110°F (32°C to 43°C)
water. Allow the sanitizer to contact the surfaces to
be sanitized for 5 minutes. Any sanitizer must be
used only in accordance with the manufacturer's
instructions.
Place all parts in the sanitizing solution for 5
minutes, then remove and let air dry completely
before assembling in machine.