Stoelting F431 Service Manual page 14

Hide thumbs Also See for F431:
Table of Contents

Advertisement

IntelliTec Control Setting Specifi cations
Basic Menu
Advanced Menu
Storage Menu
* The CutOut value needs to be adjusted to product requirements. Refer to the 2183408 - Specifi cation Sheet for F431
Control located in the plastic pouch behind the header panel.
DISPLAY
Value
CutOut
*
Cut In T
19°F
Cycles
20
Stir On
15 sec
Stir Off
300 sec
DISPLAY
Value
On Time
28 sec
Off Time
450 sec
Stb Time
120 sec
Sl1DrvOn
120 sec
Sl1DrOff
180 sec
Sl2CutIn
32°F
Sl2CtOut
28°F
DftOffTm
600 sec
DISPLAY
Value
Refriger
Cabinet
CabCutIn
38°F
CabCtOut
34°F
Cab Off
13 min
Cab On
130 sec
Table 1-1 IntelliTec Control Setting Specifi cations
MODE
DEFINITION
Serve
Amp draw setting for cut out
Serve
Temperature setting for cut in
Serve
Freezing cycles before going into Standby Mode
Serve
Stir-only on time
Serve
Stir-only off time
MODE
DEFINITION
Standby
Freezing cycle "on" time (runs on timers only)
Standby
Freezing cycle "off" time
Standby
Total time in mode
Sleep 1
Drive motor "on" timer
Sleep 1
Drive motor "off" timer
Sleep 2
Cut in temperature
Sleep 2
Cut out temperature
No Sensor Default "off" time. Used in case of sensor failure
MODE
DEFINITION
All
Set to None, 1 Hopper, 2 Hopper, or Cabinet
All
Refrigerated cab cut in temperature
All
Refrigerated cab cut out temperature
No Sensor Default "off" time. Used in case of sensor failure
No Sensor Default "on" time. Used in case of sensor failure
6