Contents 18. Disposal Requirements; Unit Specifications; Technical Specifications; Electrical Specifications - Daikin EBHQ006BAV3 Installation Manual

Unit for air to water heat pump system
Hide thumbs Also See for EBHQ006BAV3:
Table of Contents

Advertisement

Symptom 5: The water pressure relief valve leaks
P
OSSIBLE CAUSES
Dirt is blocking the water pressure
relief valve outlet.
Symptom 6: The user interface displays "n
certain buttons
P
OSSIBLE CAUSES
The current permission level is set to
a level that prevents using the
pressed button.
Symptom 7: Space heating capacity shortage at low outdoor
temperatures
P
OSSIBLE CAUSES
Backup heater operation is not
activated.
The backup heater equilibrium
temperature has not been
configured correctly.
Too much heat pump capacity is
used for heating domestic hot water
(applies only to installations with a
domestic hot water tank).
Symptom 8: Temperature values displayed on the remote controller (user
interface) are displayed in °F instead of °C
P
OSSIBLE CAUSES
You accidentally changed the setting
to view the temperature values in °F
by pushing the ib and jb
buttons simultaneously.

17.3. Error codes

When a safety device is activated, the user interface LED will be
flashing, and an error code will be displayed.
A list of all errors and corrective actions can be found in the
installation manual of the EKCB indoor manual.
18. D
ISPOSAL REQUIREMENTS
Dismantling of the unit, treatment of the refrigerant, of oil and of other
parts must be done in accordance with the applicable legislations.
Installation manual
18
C
ORRECTIVE ACTION
Check for correct operation of the
pressure relief valve by turning the
red knob on the valve counter
clockwise:
• If you do not hear a clacking sound,
contact your local dealer.
• In case the water keeps running out
of the unit, close both the water inlet
and outlet shut-off valves first and
then contact your local dealer.
n " when pressing
n
n
C
ORRECTIVE ACTION
Change the "user permission level"
field setting [0-00], refer to the
chapter
"Field settings" in the EKCB
installation
manual.
C
ORRECTIVE ACTION
Check that the "backup heater
operation status" field setting [4-00]
is turned on, refer to the chapter
"Field settings" in the EKCB
installation
manual.
Check whether or not the thermal
protector of the backup heater has
been activated (refer to
"5.2. Main
components of the outdoor unit" on
page
6, "Backup heater thermal
protector" in the installation manual
of the EKMBUH for location of the
reset button).
Check if booster heater and backup
heater are configured to operate
simultaneously (field setting [4-01],
refer to the chapter
"Field settings" in
the EKCB installation
manual).
Check whether or not the thermal
fuse of the backup heater is blown
(refer to
"5.2. Main components of
the outdoor unit" on page
6, "Backup
heater thermal fuse" in the
installation manual of the EKMBUH
for location of the reset button).
Raise the
equilibrium temperature
'
field setting [5-01] to activate backup
heater operation at a higher outdoor
temperature.
Check that the
space heating priority
'
temperature
field settings are
'
configured appropriately:
Make sure that the 'space heating
priority status' field setting [5-02] is
enabled.
Raise the 'space heating priority
temperature' field setting [5-03] to
activate booster heater operation at
a higher outdoor temperature.
C
ORRECTIVE ACTIONS
To change the display back to °C,
push ib and jb buttons
simultaneously for 5 seconds.
Execute same procedure to change
back to the °F display. The default
temperature display is in °C.
19. U
NIT SPECIFICATIONS
Technical specifications
Nominal capacity
(a)
• Cooling
• Heating
Dimensions H x W x D
Weight
• Machine weight
• Operation weight
Connections
• water inlet/outlet
Field installed waterpiping
• Minimum pressure
resistance
• Minimim temperature
resistance
• Recommended diameter
Refrigerant
• Type
• Charge
Expansion vessel
• Volume
• Pre-pressure
• Maximum working pressure
(MWP)
Pump
• Type
• No. of speed
• Nominal ESP
(a)
• Cooling
• Heating
Sound level
• Sound power cooling
• Sound pressure cooling
• Sound power heating
• Sound pressure heating
Internal water volume
Pressure relief valve
water circuit
Operation range - water side
'
• Heating
(a)
• Cooling
• Domestic hot water by heat
pump
Operation range - air side
• Heating
(a)
• Cooling
• Domestic hot water by heat
pump
(a) Only if connected to EKCBX008BAV3
(b) MBSP = Male British Standard Pipe
Electrical specifications
Power circuit
• Phase
• Frequency
• Voltage
Maximum running current
(b)
• Cooling
• Heating
(a) Equipment complying with EN/IEC 61000-3-12
(b) Only if connected to EKCBX008BAV3
(*) European/International Technical Standard setting the limits for harmonic
currents by equipment connected to public low-voltage systems
with input current >16 A and ≤75 A per phase
EBHQ006BAV3
Refer to the Technical Data
Refer to the Technical Data
(mm)
805 x 1190 x 360
(kg)
(kg)
1" MBSP
(bar)
(°C)
(inch)
R410A
(kg)
(l)
(bar)
(bar)
water cooled
49.7
(kPa)
47.2
(kPa)
(a)
63
(dBA)
(a)
48
(dBA)
61
(dBA)
48
(dBA)
(l)
(bar)
+15~+50
(°C)
+5~+22
(°C)
+25~+80
(°C)
–15~+25
(°C)
+10~+43
(°C)
–15~+35
(°C)
EBHQ006BAV3
(Hz)
(V)
230 (±10%)
(a)
(A)
16.25
(A)
(*)
Unit for air to water heat pump system
EBHQ008BAV3
95
99
(b)
4
65
1
1.7
6
1
3.0
3
45.8
34.0
63
50
62
49
5.5
3
EBHQ008BAV3
1~
50
18
EBHQ006+008BAV3
4PW64602-1D – 12.2010