Schumacher 10 Amp Instruction Manual

Schumacher 10 Amp Instruction Manual

Automatic & manual operation 2/10 amp; 2/15/100 amp for 6 & 12 volt batteries
Table of Contents

Advertisement

Available languages

Available languages

INSTRUCTION MANUAL
Working in the vicinity of a lead-acid battery is dangerous. Batteries generate explosive gases
during normal battery operation. For this reason, it is of utmost importance that each time
before using your charger, you read this manual and follow the instructions exactly.
A.
1.
Before you use your battery charger, be sure to read all in-
structions and cautions printed on:
• Battery Charger
• Battery
• Vehicle or unit using battery
2.
Use battery charger on LEAD-ACID type rechargeable bat-
teries only, such as used in automobiles, trucks, tractors,
airplanes, vans, RVs, trolling motors, etc. Charger is not in-
tended to supply power to low-voltage electrical system other
than in an automotive application.
WARNING: Do not use battery charger for charging dry-cell
batteries that are commonly used with home appliances.
These batteries may burst and cause injury to persons and
damage to property.
3.
Use only attachments recommended or sold by manufac-
turer. Use of non-recommended attachments may result in
fire, electric shock, or injury.
4.
When disconnecting the battery charger, pull by the plug
not by the cord. Pulling on the cord may cause damage to
cord or plug.
5.
Position battery power cord so it cannot be stepped on,
tripped over, or subjected to damage or stress.
6.
Do not operate charger with damaged cord or plug. Have
cord replaced immediately.
7.
Do not operate charger if it has received a sharp blow, been
dropped, or otherwise damaged in any way. Take it to a quali-
fied professional for inspection and repair.
8.
Do not disassemble charger. Take it to a qualified profes-
sional when service or repair is required. Incorrect reassem-
bly may result in electric shock or fire.
9.
To reduce risk of electric shock, unplug charger from outlet
before attempting any maintenance or cleaning.
10. Do not use an extension cord unless absolutely necessary.
Use of an improper extension cord could result in fire or
electric shock. If an extension cord must be used, make
sure that:
• Pins on plug of extension cord are the same number, size,
and shape as those of plug on charger.

Important Safety Instructions

Read instructions and rules for safe operation carefully.
GENERAL BATTERY SAFETY
For
AUTOMATIC & MANUAL OPERATION
Lead-Acid
Model:
Batteries
For 6 & 12 Volt Batteries
–Save–
• Extension cord is properly wired and in good electrical
condition.
• Wire size is large enough for AC ampere rating of charger,
as specified below:
AC INPUT RATING, AMPERES
Equal to or
Greater than
0
2
6
11. Always charge battery in a well ventilated area.
NEVER operate in a closed-in or restricted area without ad-
equate ventilation.
WARNING: Risk of explosive gas.
12. Use charger as far away from battery as DC charger cables
permit.
13. Do not expose charger to rain or snow.
14. NEVER charge a frozen battery. If battery fluid (electrolyte)
is frozen, bring into a warm area to thaw before charging.
15. NEVER allow battery acid to drip on charger when reading
specific gravity or filling battery.
16. NEVER set a battery on top of charger.
17. NEVER place charger directly above battery being charged.
Gases from battery will corrode and damage charger.
18. NEVER touch the battery clamps together when the charger
is energized.
1
PS- 1022MA
PS-2100MA
but less than
25
2
18
3
18
8
18
2/10 Amp
2/15/100 Amp
AWG SIZE OF CORD
Length of Cord, Feet
50
100
150
18
18
16
18
16
14
16
12
10
00-99-000297/202

Advertisement

Table of Contents
loading

Summary of Contents for Schumacher 10 Amp

  • Page 1: Important Safety Instructions

    For this reason, it is of utmost importance that each time before using your charger, you read this manual and follow the instructions exactly. Before you use your battery charger, be sure to read all in- structions and cautions printed on: •...
  • Page 2: Preparing To Charge

    Im- proper connection can result in a risk of electric shock. This battery charger is for use on a nominal 120 Volt circuit, and has a grounding plug that looks like the plug illustrated in sketch During operation do not place the charger or its cables on the vehicle seat or carpeting.
  • Page 3: Battery Charger Controls

    Two switches permit Battery Type and Charge Rate selection. Switch #1 (3 Modes) Mode 1 – Manual Position: Use for charging in 2 Amp or 10 Amp charge rates on 12 Volt batteries only. This charging must be monitored and manually stopped when the battery is charged.
  • Page 4: Dc Connection Precautions

    No. 5. If positive post is grounded to the chassis, see No. 6. For a negative-grounded vehicle, connect POSITIVE (RED) clamp from battery charger to POSITIVE (POS, P,+) un- grounded post of battery. Connect NEGATIVE (BLACK) clamp to vehicle chassis or engine block away from battery.
  • Page 5: Output Control

    When the meter indicates an intermittent current flow to the battery. Very little maintenance is required for the battery charger. Follow common sense in wiping the charger clean and store in a clean, dry area. After use, wipe all battery corrosion and other dirt or oil from clamps, cords, and the charger case.
  • Page 6: Troubleshooting

    The battery charger is designed to work automatically. However, if a problem does occur, check the following: PROBLEM No meter reading. Charger will not turn on (when properly connected to power) in automatic mode only. Charger will not turn OFF.
  • Page 7: Limited Warranty

    CHASER AT RETAIL OF THIS PRODUCT. THIS LIMITED WAR- RANTY IS NOT TRANSFERABLE. Schumacher Electric Corporation warrants this battery charger for 2 years from date of purchase at retail against defective ma- terial or workmanship. If such should occur, the unit will be re- paired or replaced at the option of the manufacturer.
  • Page 8: Instrucciones Importantes De Seguridad

    Siempre utilice el cargador de baterías en un área abierta y bien ventilada. NUNCA se debe fumar ni debe haber chispas o llamas cerca de la batería o el motor. ¡Las baterías producen gases explosivos! 2/10 Amp PS-2100MA 2/15/100 Amp CALIBRE (AWG) DEL CABLE...
  • Page 9 Selector # 1 (3 métodos de carga) Método 1 – Posición manual Se usa para cargar en 2 Amp. ó 10 Amp., sólo para baterías de 12 voltios. Este método de carga se debe vigilar y detener manualmente cuando la batería está cargada. La sobrecarga dañará la batería.
  • Page 10 10 12 FULLY DISCHARGED BATTERY Initial charge current to the battery is typically 10 Amp. The needle points toward the 25% mark. El medidor funciona igual al del PS-2052A (ver abajo) excepto que no tiene una zona de diodos emisores de luz (LED) o una zona de arranque (Start).
  • Page 11: Mantenimiento

    INSTRUCCIONES DE OPERACIÓN: CÓMO CARGAR UNA BATERÍA FUERA DEL VEHÍCULO UNA CHISPA CERCA DE LA BATERÍA PUEDE CAUSAR QUE EXPLOTE LA BATERÍA. PARA REDUCIR EL RIESGO DE CHISPAS CERCADE LA BATERÍA: Verifique la polaridad de las terminales de la batería. Terminal POSITIVO (POS, P, o +) de la batería normalmente es de mayor diámetro que el NEGATIVO (NEG, N, -) Asegure un cable de batería aislado calibre 6 (AWG) de por lo menos...
  • Page 12: Resolución De Problemas

    Schumacher Electric Corporation, 801 Business Center Drive, Mount Pros- pect, Illinois, 60056-2179, hace esta garantia limitada al comprador origi- nal al por menor de este producto. Esta garantia limitada no es transferible.

Table of Contents