York Predator Z series Installation Instructions Manual page 4

R-410a. w/smart equipment. 3-5 ton 60 hertz
Table of Contents

Advertisement

5370596-YIM-C-0518
Nomenclature
Product Category
Z = A/C, Single Pkg., R-410A
Product Identifier
T = Pkg AC Ultra High Eff
C = Cooling Only
E = Electric Heat
Two Stage Natural Gas Heat Options
N = 2 Stage Gas Aluminized Steel
S = 2 Stage Gas Stainless Steel
P = 2 Stage Low Nox Gas Aluminized Steel
Q = 2 Stage Low Nox Gas Stainless Steel
00 = Cooling Only
06 = 60 MBH Input (037, 049)
08 = 80 MBH Input (037, 049, 061)
12 = 120 MBH Input (037, 049, 061)
16 = 160 MBH Input (061)
03 = 3 KW (037)
06 = 6 KW (037,049,061)
09 = 9 KW (037,049,061)
15 = 15KW (037,049,061)
20 = 20 KW (049,061)
24 = 24 KW (061)
P = VFD IntelliSpeed Std Static
R = VFD IntelliSpeed High Static
S = VFD w/Byp IntelliSp Std Static
U = VFD w/Byp IntelliSp Hi Static
4
®
3-5 Ton York
Z T 037 C
Nominal Cooling Capacity
037 = 3 Ton
049 = 4 Ton
061 = 5 Ton
Heat Type
Heat Capacity
Gas MBH Input (Unit Size Allowed)
Electric Heat (Unit Size Allowed)
Blower Option
Outdoor Air Option
A = No Economizer
B = Economizer w/Barometric RLF
D = Economizer w/Power EXH
H = Motorized Damper
Model Number Nomenclature
00
A 2 A 1
A
A = No Sensors
B = PHM (Phase Monitor)
C = DFS (Dirty Filter Switch)
D = SSD (Supply Air Smoke DET)
E = RSD (Return Air Smoke DET)
F = PHM,DFS
G = PHM,SSD
H = PHM,RSD
J = DFS,SSD
K = DFS,RSD
Voltage
L = SSD,RSD
M = PHM,DFS,SSD
2 = 208/230-3-60
N = PHM,DFS,RSD
4 = 460-3-60
P = PHM,SSD,RSD
5 = 575-3-60
Q = DFS,SSD,RSD
R = PHM,DFS,SSD,RSD
1 = No Service Options
2 = DSC (Disconnect Switch)
3 = NCO (Non-PWR Conv. Outlet)
4 = PCO (Powered Conv. Outlet)
5 = DSC,NCO
6 = DSC,PCO
A
A 1
A 1
Product Generation
1 = First Generation
2 = Second Generation
Cabinet Options
A = Std Cabinet
E = SSD (SST Drain Pan)
R = Reverse Drain Pan
Additional Options
1 = STD Throwaway Filter
2 = 2" Pleated Filters (Merv 8)
3 = 4" Pleated Filters (Merv 13)
4 = Coil Guard (CG), STD Filter
5 = 2" Pleated Filter,CG
6 = 4" Pleated Filter,CG
Refrigeration
A = Standard Refrigeration
B = ECC (E-Coat Cond Coil)
C = EEC (E-Coat Evap Coil)
F = ECC,EEC
Controls Option
A = Stand Alone Smart Equipment™
C = BACnet MSTP,Mdbs,N2 COM Card
D = CPC Control, DFS, APS
F = Fault Detection Diagnostics
G = Novar UCM Ctrl, DFS, APS
H = Hnywll Excel 10 CTRL,DFS,APS
M = Verasys Single Zone
K = Verasys Change Over Bypass
L = Verasys VAV
Q = Verasys Single Zone W/FDD
R = Verasys COBP W/FDD
T = Verasys VAV W/FDD
Sensors
Service Options
Johnson Controls Ducted Systems