SDM-2020 Satellite Demodulator
B.10
OEM LCD Option (Requires FAST Upgrade)
The OEM LCD option permits the user to specify three pieces of information in the
equipment.
•
•
•
If the manufacturer is to program this data into the equipment prior to delivery, the user
must specify the three strings. The manufacturer requires the string information ( as
specified in Column 4). The instructions for programming of the data via equipment's
remote port is as follows:
Note: The <add/REM_ command is issued.
Command/
Parameter
Response
Program OEM String
Command:
1
Response:
Status:
Response:
(see Note 1)
Program OEM String
Command:
2
Response:
Status:
Response:
(see Notes 1 and 2)
Program OEM String
Command:
3
Response:
Status:
Response:
(see Note 1)
Notes:
1. A space in the display is created by the exponent character (^) in the string.
2. If a single question mark (?) is used as the OEM string 2, then the current version of
the M&C firmware is displayed. This is the usual entry.
3. Spaces are not allowed in OEM string 3. Use an underscore ( _ ) as a separator
between characters, see example:
Incorrect: xxxx yyyy
Correct:
Rev. 3
Line 1 of the LCD display.
Line 2 of the LCD display.
The identification of the unit when the remote port is interrogated for
"equipment type."
Remote Specification
<add/OES1_xxxxxxxxxxxxxxxx'cr'
>add/OES1_xxxxxxxxxxxxxxxx'cr''If']
<add/OES1_'cr'
>add/OES1_xxxxxxxxxxxxxxxx'cr''If']
<add/OES2_xxxxxxxxxxxxxxxx'cr'
>add/OES2_xxxxxxxxxxxxxxxx'cr''If']
<add/OES2_'cr'
>add/OES2_xxxxxxxxxxxxxxxx'cr''If']
<add/OES3_xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx'cr'
>add/OES3_xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx'cr''l
f']
<add/OES3_'cr'
>add/OES3_xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx'cr''I
f']
xxxx_yyyy
Remote Control Operation
String Information
Where : xxxxxxxxxxxxxxxx =
16-character string to be displayed
on Line 1 of the modem LCD.
Where : xxxxxxxxxxxxxxxx =
16-character string to be displayed
on Line 2 of the modem LCD.
Where :
xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx =
32-character string returned when
the ET_ (equipment type) command
is executed via the remote port..
B–27