Avs System Enable And Quick Programming Commands; Setting The Real-Time Clock - Honeywell ADEMCO VISTA SERIES Programming Manual

Hide thumbs Also See for ADEMCO VISTA SERIES:
Table of Contents

Advertisement

R E P E A T O P T I O N
0 - 4
X
R A N D O M I Z E
0 = N O 1 = Y E S
X

AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS

Applies to an AVS system using an ECP connection to the control.
1. Install the AVS module according to its instructions.
2. Use one of the control's AVS Quick Program commands as follows (see Quick Program Command Results below for
results of each command):
• installer code + [#] + [0] + 3: enable AVS operation without panel sounds on the AVST speaker
• installer code + [#] + [0] + 4: enable AVS operation and enable panel sounds on the AVST speaker
3. Use data field ∗55 Dynamic Signaling Priority to select the desired reporting paths (phone line and/or GSMV) and path for
AAV communication.
4. To undo the Quick Command programming, use the following commands:
• installer code + [#] + [0] + 5: remove all options set by [#] + [0] + 3 quick command
• installer code + [#] + [0] + 6: remove all options set by [#] + [0] + 4 quick command
Quick Program Command Results
When either the #03 or #04 Quick Program command is used, the following are automatically programmed and no longer
available for other control panel purposes.
Pre-Programmed
Output Function No.
VISTA-15P series
(∗80 mode)
22 (zone type 60, relay 07)
23 (zone type 61, relay 08)
24 (zone type 62, relay 08)
Output Relay No.
07 (addr 08, relay pos 2)
08 (addr 08, relay pos 1)
(∗79 mode)
Protection Zone
4229 zn 24 (zt 81, addr 08)
(∗56/∗58 mode)
Device Address
address 08 (AVS module)
Data Field ∗91

SETTING THE REAL-TIME CLOCK

IMPORTANT: The Real-Time Clock must be set before the end of the installation.
NOTE: All partitions must be disarmed before the date/time can be set.
1. Master Code + [#] + [6] [3]
2. Press [∗] when the time/date is displayed.
A cursor appears under the first digit of the hour.
To move cursor ahead, press [ ∗ ]. To go back, press [#].
• Enter the 2-digit hour setting.
• Enter the 2-digit minute setting.
• Press [1] for PM or [2] for AM.
• Enter the last two digits of the current year.
• Enter the 2-digit month setting.
• Enter the 2-digit day setting.
3. To exit, press [∗] when cursor is at the last digit, or wait 30 seconds.
Repeat Option
0 = do not repeat
1 = repeat weekly
2 = repeat biweekly (every
other week)
3 = repeat every third week
4 = repeat every fourth week
Press [∗] to continue.
Randomize
0 = no
1 = yes
Press [∗] to continue and
return to ENTER SCHED
NO. prompt to program the
next schedule.
#03 Command
VISTA-20P series
46 (zone type 60, relay 15)
47 (zone type 61, relay 16)
48 (zone type 62, relay 16)
15 (addr 11, relay pos 2)
16 (addr 11, relay pos 1)
4229 zn 48 (zt 81, addr 11)
address 11 (AVS module)
AAV enabled
AAV enabled
Enter the desired repeat option for this schedule.
e.g., To make a schedule that happens everyday you would
select all days with a repeat count of 1. To make a schedule that
runs for one week then stops, select everyday with a repeat
count of 0.
(For events 01 and 11)
If selected, the scheduled start and stop times will vary within 60
minutes of the "hour" time. For example, if a schedule is set to
start at 6:15pm, it will do so the first time 6:15pm arrives, but on
subsequent days it will start anytime between 6:00 and 6:59 p.m.
NOTE: Do not use the random option if the start and stop times
are within the same "hour" setting, otherwise unpredictable
results may occur (e.g., the randomized stop time may occur
before the start time).
VISTA-15P series
Same as #03 plus:
17 (zone type 14, relay 05)
18 (zone type 22, relay 05)
19 (zone type 39, relay 06)
20 (zone type 33, relay 06)
21 (zone type 36, relay 06)
Same as #03 plus:
05 (addr 08, relay pos 4)
06 (addr 08, relay pos 3)
Same as #03 command
Same as #03 command
AAV enabled
– 33 –
#04 Command
VISTA-20P series
Same as #03 plus:
41 (zone type 14, relay 13)
42 (zone type 22, relay 13)
43 (zone type 39, relay 14)
44 (zone type 33, relay 14)
45 (zone type 36, relay 14)
Same as #03 plus:
13 (addr 11, relay pos 4)
14 (addr 11, relay pos 3)
Same as #03 command
Same as #03 command
AAV enabled

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents