Status Read Commands

Format
The command is sent from PC to the projector with
the format below;
"CR" [Command] [CR]
Command: one character (refer to the command
table below.)
The projector decodes the command and returns the
'Character string' with the format below;
Command
CR0
CR6
Temperature Read
The tables on page 98 show the typical command lists for controlling the projector. Please consult your local
dealer for further information of other commands.
99
Return
Function
value
00
80
40
20
10
28
24
04
Status Read
21
81
88
2C
8C
%1 %2
?
Projector status
Power On
Stand-by mode
Countdown
Cooling down
Power Malfunction
Cooling down at the temperature anomaly
Cooling down at Power Management mode
Power Management mode after Cooling down
Cooling down after the projector is turned off when the lamps
are out.
Stand-by mode after Cooling down when the lamps are out.
Stand-by mode after Cooling down at the temperature
anomaly.
Cooling down when the projector is turned off by the shutter
management function.
Stand-by mode after Cooling down by the shutter
management function.
%1 = Temperature at Sensor 1 (˚C)
%2 = Temperature at Sensor 2 (˚C)
(ex.) %1 = 12.3 (˚C), %2 = 23.4 (˚C)
--> The projector returns " 12.3 23.4" .
( For each sensor, two digit and the tenth place numbers are
displayed with a space between each temperature.)