Fitting An Aquamaster Pulsed Output Socket With Serial Communications - ABB CalMaster2 Instruction Manual

Tests the integrity of a flow metering system by altering a number of flow measurement parameters and measuring the values returned from the flow measuring system.
Hide thumbs Also See for CalMaster2:
Table of Contents

Advertisement

Field and Software Tools
CalMaster2 and CheckMaster

3.3.5 Fitting an AquaMaster Pulsed Output Socket with Serial Communications

B
Fig. 3.10 Fitting an AquaMaster Pulsed Output Socket with Serial Communications
To fit an AquaMaster pulsed output socket with serial communications:
1.
Turn off the power to the AquaMaster and remove the covers – see Section 3.3.2, page 12.
Disconnect and withdraw the pulsed output cable A.
2.
Remove and discard the gland B.
3.
Feed the socket lead into the AquaMaster and fit the socket (MGFA0609-O) C.
4.
Connect the sensor cable D.
5.
6.
Replace the covers – see Fig. 3.7, page 12.
IM/VCM2 Issue 6
O/P COM
Grey/Blue
O/P1
Orange
O/P2
Blue
GND
Green
RI
Yellow
CTS
Yellow/Red
RTS
Red/Black
TXD
Brown
RXD
Violet/Red
D
A
3 Installation
C
15