How do you work it? A Quick Overview
®
AFS FILTERS CAN BE DEPLOYED IN ONE OF TWO PRIMARY MODES.
All Live (Normal Mode). In this mode, the 12 filters per channel are available to be deployed
as feedback occurs throughout a performance.
Six Live, Six Fixed (Mixed Mode). In this mode, half of the filters can be deployed when set-
ting up and "ringing out" the system. These "fixed" filters will remain in place until cleared.
This leaves the remaining six filters in the "live" mode for the remainder of the performance.
Those live filters will deploy to address feedback as needed for a limited (and selectable)
amount of time.
TO SELECT BETWEEN THOSE MODES:
1. On power up, press and hold channel 1 AFS button until the Channel 1 meters show every
other LED lit. Once the AFS button is released the various modes can be selected.
2. Pressing the Channel 1 AFS button cycles through the 3 menus, indicated by each of the
three LED lights on the Channel 1 output meter.
3. Pressing the Channel 1 AFS button twice will light up the Third LED on the Channel 1 out-
put meter indicating that you are now in the menu where you can select between AFS
Normal (12 Live Filters) and AFS Mixed (6 Fixed Filters & 6 Live Filters).
4. Now press the Channel 2 AFS to select either the Normal or Mixed mode by toggling the
LED on the Channel 2 output meter.
5. Pressing and holding the Channel 1 AFS button will allow you to exit the power up menus;
or, proceed to instruction #4 in "Filter Lift" selections on the following page.
iEQ-15 and iEQ-31
Power Up Prompt
Power Up Menu
AFS Normal vs. 6-Fixed/6-Live Menu
CHANNEL 1
CHANNEL 1
CHANNEL 2
®

Advertisement

loading

Summary of Contents for dbx iEQ-15

  • Page 1 How do you work it? A Quick Overview ® ® AFS FILTERS CAN BE DEPLOYED IN ONE OF TWO PRIMARY MODES. All Live (Normal Mode). In this mode, the 12 filters per channel are available to be deployed as feedback occurs throughout a performance.
  • Page 2 LIVE FILTERS CAN SET TO ONE OF THREE FILTER LIFT SELECTIONS: This sets the amount of time a live filter remains in effect before it becomes disengaged. The 3 Live Filters settings are: CHANNEL 2 Live Filter Lift Time Menu •...
  • Page 3 FRONT PANEL CONTROL LOCK OUT FEATURE 1. On power up, press and hold channel 1 AFS button until the Channel 1 meters show every other LED lit. Once the AFS button is released, the various modes can be selected. 3. Pressing the Channel 1 AFS button cycles through the menus. This is indicated by changes in the LED’s on the Channel 1 output meters.
  • Page 4 FILTERS CAN BE CLEARED AND RE-SET • To clear all filters (both Live and Fixed), depress the AFS button for a few seconds until the LED meter adjoining it flashes, indicating that the filters have been cleared. • Live Filters can be cleared, leaving Fixed Filters in place. Turning the unit off re-sets (clears) the live filters but not the fixed filters.

This manual is also suitable for:

Ieq-31