INSTALLATION
Electrical access is via a 20 mm hole beneath the element cover for mounting with an approved weatherproof
electrical conduit nipple. For entry to the element cover remove the two fixing screws.
Connect all ACTIVE and NEUTRAL wires in accordance with the wiring diagram which is also included at the rear
of the element access cover. Ensure the incoming EARTH wire is securely fixed to the earth post provided on the
heater case. Inspect and ensure that all wiring links are secure prior to fixing the access cover and turning the
POWER ON.
EARTH
To ensure the over-temperature and energy cut-out is set, press the (red) 'reset' button on the Thermostat
Note that the unit must be always connected to a continuous tariff (not off peak).
Disconnect all power prior to installation and commissioning. This appliance is designed for single phase 240
Volts, AC mains electrical operation.