XHF Spray Gun
For spraying viscous materials at high flow rates. For professional use only.
Part No. 262854, Series A
®
Includes an XHD
RAC
7250 psi (50 MPa, 500 bar) Maximum Working Pressure
Important Safety Instructions
Read all warnings and instructions in this
manual. Save all instructions.
Guard and XHD429 SwitchTip
3A2799C
EN
ti19264a
II 2 G Ex h T6 Gb

Advertisement

Table of Contents
loading

Summary of Contents for Graco XHF

  • Page 1 Instructions - Parts XHF Spray Gun 3A2799C For spraying viscous materials at high flow rates. For professional use only. Part No. 262854, Series A ™ ® ™ Includes an XHD Guard and XHD429 SwitchTip 7250 psi (50 MPa, 500 bar) Maximum Working Pressure...
  • Page 2: Table Of Contents

    Graco Standard Warranty ....16 Graco Information ......16...
  • Page 3: Warnings

    Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
  • Page 4 Warnings WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system com- ponent.
  • Page 5: Operation

    Follow the Pressure Relief Procedure whenever injury occur. Additional cards (part no. 222385) are you see this symbol. available at no charge from Graco. System Requirements This equipment stays pressurized until pressure is Pressure drain valves are recommended in the system;...
  • Page 6: Operation

    Operation Operation 8. Use a full-open, full-close trigger action. Hold the gun about 14 in. (350 mm) from and at right angles to the work surface. Don’t swing the gun in an arc. Practice to find the best length and speed of stroke. To reduce the risk of component rupture, and serious Adjust the Spray Pattern injury, including fluid injection, do not exceed the...
  • Page 7: Gun Care

    Operation Gun Care If the spray tip clogs while spraying 1. Stop spraying immediately. 2. Lock the gun trigger lock. Rotate the RAC SwitchTip handle 180°. See Fig. 4. • To reduce the risk of fluid injection or splashing in the eyes or on the skin, do not point gun at 3.
  • Page 8: Flush The Gun

    Operation Flush the Gun 7. Now trigger the gun into the flushing fluid supply pail. Circulate the fluid until the system is thoroughly flushed. 8. After gun is thoroughly flushed, relieve pressure. To reduce the risk of serious injury, including splashing fluid in the eyes or on the skin, or static electric dis- charge when flushing: •...
  • Page 9: Service

    Service Service 3. Unscrew the valve seat (2a). Remove the gasket (2b). See F . 6. To reduce the risk of serious injury from fluid injection or splashing, always follow the Pressure Relief Proce- dure on page 5 before servicing the gun. Disassembly for Repair or Cleaning NOTE: If replacing only the needle and seat, step 4 and...
  • Page 10: Reassembly

    Service 5. Loosen the setscrew (15) then remove the fluid 8. Clean all parts and cavities thoroughly with a com- housing (22) from the gun body (1). See F . 8. patible flushing fluid. Dry with a rag or compressed air.
  • Page 11 Service 3. Place the gasket (2b) on the valve seat (2a). Grease 5. If the spring (19) was removed, grease the spring the threads of the valve seat (2a) then install into the adjuster (20) and place the spring on the adjuster fluid housing (22).
  • Page 12: Test The Gun After Service

    Service 7. Position the trigger (24) on the gun body. Insert the Test the Gun After Service pivot pin (23) into the top hole (A) and secure with the screw (13) on the other side. Ensure there is an 1. Lock the gun trigger lock. Connect a hose to the e-clip (26) on one end of the trigger pin (18).
  • Page 13: Parts

    Parts Parts ti19282a Must install as shown with the notch on the bottom. Ref Part Description Ref Part Description 189990 ADJUSTER, spring BODY, gun 110637 SCREW, adjusting 237260 KIT, needle and seat 16P780 HOUSING, fluid SEAT, valve 187965 PIN, pivot GASKET 189974 TRIGGER, gun NEEDLE...
  • Page 14: Accessories

    Parts Needle and Seat Kits The needle and seat are available only in kits that include items 2a through 2e. The standard non-diffused needle and seat kit, 237260, includes all OEM parts and has the number 125 stamped on the needle and seat. It is recommended for use with mastics, sealers and other high viscosity mate- rials which have fillers that cannot easily pass through a diffuser.
  • Page 15: Technical Data

    Technical Data Technical Data Maximum Working Pressure ..... 7250 psi (50 MPa, 500 bar) Fluid orifice size ....... 0.125 in.
  • Page 16: Graco Standard Warranty

    With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.