Download Print this page

Sanyo ECO G SGP-EGW190M2G2W Brochure & Specs page 4

Gas driven vrf m series
Hide thumbs Also See for ECO G SGP-EGW190M2G2W:

Advertisement

ECO G 2 Way Heat Pump VRF System
ECO G W-Multi for Heat Pump
Applications
The new and improved M Series heat pump
(2 Way) not only offers improved performance
but
also
increased
flexibility.
Now
available
multi-systems,
many
combinations
are
possible,
from 13HP to 50HP, allowing for more power
and enabling accurate matching of a system building
load. Additional new features include part load engine
management and compressor run hour equalisation.
• Reduced gas consumption by Miller-cycle engine
• Reduced electrical power consumption by using DC motors
• New lightweight design by use of aluminium engine block
reduces weight by 110kg
• Part load efficiencies increased
• Connectability increased - now up to 48 indoor units
• Multi-systems with combinations from 13HP up to 50HP
• 200m maximum allowable piping length (L1) (equivalent - refer
to technical manual)
• Diversity ratio 50-180%
• Extended pipe runs (total 500m)
• Industry leading sound levels
HP
13
SGP-EW120M2G2W
Model name
Cooling
kW
35.50
Heating
STD
40.00
Capacity
Heating Low temp*1
kW
42.50
Hot water
12.00
Cooling
kW
0.85
Electricity
Heating
Cooling
kW
24.50
Gas consumption
Heating
STD
28.10
kW
Heating
LOW
36.80
Cooling
1.40
COP
Heating
1.37
AVE
1.39
Max COP (inc hot water) Cooling
1.87
Height
Size
Width
mm
Depth
Weight
kg
Starter amperes
(A)
Gas
Piping connection
Liquid
Inches (mm)
Balance
Pipe fuel gas
Pipe exhaust drain
Operation sound
dB(A)
Indoor/outdoor capacity ratio
Number of indoor connections
32
* In case of these combinations EGW190M2G2W is able to connect as W-multi instead of EW190M2G2w.
* 1: Low temp condition: Outdoor temperature 2 C˚.
Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details.
Please refer to tube sizing charts for pipe selections and pipe length parameters.
Capacity Hot Water is available when outside ambient air temperature is above 7C˚.
6
as
• Silent mode offers a further 2dB(A) reduction
• Chiller option
- 13HP (25kW cooling - 30kW heating)
- 25HP (56kW cooling - 67kW heating)
• 10,000 run hours between engine service intervals (equivalent
to one maintenance every 3.2 years*)
• Full heating capacity down to -20°C
• No defrost cycle
* Assuming 3120 running hrs per year - 12 hrs x 5 days x 52 weeks
16
20
25
SGP-EW150M2G2W
SGP-EW190M2G2W
SGP-EW240M2G2W
45.00
56.00
50.00
63.00
53.00
67.00
75.00
16.00
20.00
25.00
1.35
1.01
1.54
31.60
38.30
60.90
36.10
43.00
58.00
47.30
56.40
64.90
1.37
1.41
1.14
1.35
1.43
1.34
1.36
1.42
1.24
1.85
1.92
1.54
1,800
790
820
850
1 1/8 (28.58)
1/2 (12.7)
5/8 (15.88)
57
58
62
50-180 %
36
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
ECO G 2 Way Outdoor Unit Specifications
Dimensions ECO G W-Multi 2 Way
Model Type
120
ø25.4
1
Gas refrigerant pipe (Gas tube)
2
Liquid refrigerant pipe (Liquid tube)
3
Refrigerant balance pipe (Balance tube)
4
Exhaust gas drain hose
5
Electrical power supply port
Inter-unit cable port
6
Fuel gas port
7
8
Condensation drain opening
9
Rain and condensation outlet
Engine exhaust outlet
10
Suspension holes
11
Anchor holes
12
Segmented display
13
Coolant intake (top)
14
Vent
15
Hot water intake
16
Hot water outlet
17
18
Cable inlet for interlock and the like
17
16
26
29
SGP-EW120M2G2W
SGP-EW120M2G2W
SGP-EW150M2G2W
SGP-EW120M2G2W
SGP-EW150M2G2W
SGP-EW150M2G2W
71.00
80.50
80.00
90.00
85.00
95.50
24.00
28.00
1.70
2.20
49.00
56.10
56.20
64.20
73.60
84.10
1.40
1.38
1.37
1.36
1.39
1.37
1.87
1.86
2,248
1,000 (+60)
1,580
30
1 3/8 (34.92)
3/8 (9.52)
R3/4 (bolt thread)
ø25 rubber hose
60
Rating Conditions: Cooling Indoor 27°C DB 19°C WB Outdoor 35°C DB 24°C WB Heating Indoor 20°C DB Outdoor 7°C DB 6°C WB
Size (mm)
150
190 and 240
ø28.58
ø15.88
ø12.7
Service Clearances for installation
ø9.52
(Units: mm)
OD: ø25 Length: 200
at least
ø28
100
ø28
G: R3/4
at least 2000
Rear
(refrigerant tubing)
ø20
4 - ø20
at least
at least
4 - ø24
100
350
Front View
(Single-unit installation)
(Multi-unit series installation)
Rp3/4
Rp3/4
1000
ø28
ø736
3
7
2
1
18
6
5
1040
271
4
1060
54
147
8
207
Rear View
242
Left Side View
275
312
461
32
33*
36*
SGP-EW120M2G2W
SGP-EW150M2G2W
SGP-EW190M2G2W
SGP-EW190M2G2W
90.00
91.50
101.00
100.00
103.00
113.00
106.00
109.50
120.00
32.00
32.00
36.00
2.70
2.20
2.02
63.20
62.80
69.90
72.20
71.10
79.10
94.60
93.20
103.70
1.37
1.41
1.39
1.35
1.41
1.39
1.36
1.41
1.39
1.85
1.90
1.89
1,800 + 100 (min distance) + 1,800 (in a straight installation)
1,610
3/4 (19.05)
61
50-130 %
48
Top View
at least
10
100
Rear
(refrigerant tubing)
at least
350
Front View
14
1000
12
400
(anchor pitch)
9
15
12
11
1800
Front View
40*
45*
50
SGP-EW190M2G2W
SGP-EW190M2G2W
SGP-EW240M2G2W
SGP-EW190M2G2W
SGP-EW240M2G2W
SGP-EW240M2G2W
112..0
127.00
142.00
126.00
143.00
160.00
134.00
142.00
150.00
40.00
45.00
50.00
2.70
2.55
3.08
76.60
99.20
121.80
86.00
101.00
116.00
112.80
121.30
129.80
1.41
1.25
1.14
1.43
1.38
1.34
1.42
1.31
1.24
1.92
1.69
1.54
1,640
1,670
1,700
1 5/8 (41.27)
63
65
7

Advertisement

loading