Denon AVR-X2400H Service Manual page 115

Integrated network av receiver
Hide thumbs Also See for AVR-X2400H:
Table of Contents

Advertisement

When the results of check item (65) are "03"
(Detection of HPD is OK / Detection of RXSENSE is OK )
Checking the EDID register. (Monitor2)
Check item(66).
Check the Monitor EDID :
① Unplug the AC cord. Plug the AC cord into a power outlet.
② Send the transmission command "m_2" from Termite.exe.
Are the first eight bytes of the returned value "00FFFFFFFFFFFF00"?
YES
Check item(67).
Checking the TMDS :
Check the TMDS waveform at the following test
point.
N1030
HDMI
HDMI
OUT 2
OUT 2
YES
NO
Check for a short circuit in the TMDS line.
If there is no problem, the HDMI Tx
[U1039] is faulty.
Replace with a new device.
HDMI Tx [U1039] is faulty.
Replace with a new device.
Recheck from
check item (3).
If it does not work, replace the PCB.
NO
Check item(68).
Check communication with the
monitor :
Are waveforms of "DDCCLK" and "DDCSDA"
observed at the test point near the HDMI output
terminal [N1030]?
N1030
HDMI
HDMI
OUT 2
OUT 2
DDCSCK
DDCSDA
YES
NO
HDMI Tx [U1039] is faulty.
Replace with a new device.
HDMI Tx [U1039] is faulty.
Replace with a new device.
Example
The first eight bytes are normally
"00FFFFFFFFFFFF00".
*If the AVR and the TV are not con-
nected via HDMI, the correct register
value cannot be verified.
less than 100KHz
5V
5V
This diagram shows an example of the DDC communica-
tion waveform.
-The high level voltage is 5V.
-The frequency of the DDC CLK is 100 KHz or less.
Check at each test point.
Voltage scale:2.0V/div
Time scale:40us/div