7.7.6 Grounding the Installation

The Outdoor Unit (ODU) must be properly grounded to protect against power surges. It is the
user's responsibility to install the equipment in accordance with Section 810 of the National Electric
Code, ANSI/NFPA No.70-1984 or Section 54 of the National Electrical Code in the country of
installation. These codes describe correct installation procedures for grounding the outdoor unit,
mast, lead-in wire and discharge unit, size of grounding conductors and connection requirements
for grounding electrodes. It is recommended that installation of the outdoor unit be contracted to
a professional installer.

7.7.7 Making the ODU Connection at the PTP 300/500/600 Series Bridge PIDU Plus

The ODU is connected to the PIDU Plus by means of a concealed RJ45 connector. The RJ45 con-
nection has been placed inside the PIDU Plus hinged cover to prevent the user from inadvertently
plugging other equipment into the ODU RJ45 socket.
CAUTION: Plugging other equipment into the ODU RJ45 socket may damage the equipment
due to the non-standard techniques employed to inject DC power into the 100BaseT connection
between the PIDU Plus and the ODU. Plugging the ODU into other equipment may damage the
ODU and/or the other equipment.
Step 1: Undo the retaining
screw and hinge back the cover
Step 3: Replace the cover and secure with the retaining screw
Installation
Step 2: Plug in the ODU into the PIDU
Plus Cable ensuring that it snaps home
53