Stanley GR30 User Manual page 17

Hydraulic grinder
Hide thumbs Also See for GR30:
Table of Contents

Advertisement

ASSIST
HANDLE
SHUTDOWN
1. Move the hydraulic system control valve to the OFF position.
2. Disconnect the hydraulic hoses from the tool: first the input (supply) hose, then the output (return) hose.
3. Place dust plugs on the couplers, as applicable.
4. Wipe the tool thoroughly with a clean dry cloth.
5. Clean any foreign matter from the grinding wheel surfaces.
CARE AND STORAGE
Clean and inspect the wheel and tool before storing.
GRINDING WHEELS
All grinding wheels are breakable. Exercise care in handling and storage to prevent damage.
1. Clean used wheels to remove any dirt, debris or grease.
2. Inspect the wheel for chips, cracks or other damage. For maximum tool performance, replace the wheel if it is
worn or defective.
TOOL
1. Clean the tool to remove any dirt, debris, or grease. Dry with compressed air or clean dry cloths.
2. Replace any damaged or missing safety labels and tags before storing the tool. Otherwise, the tool might be
improperly used by someone who is not familiar with the safety requirements.
3. Store the tool in a clean, dry, safe place.
DISPOSAL
HYDRAULIC OIL
Hydraulic oil can contaminate the air, ground and water if not properly recycled. Recycle hydraulic oil in accordance
with all State, Federal and local laws, at your local oil recycling facility.
OPERATION
MAIN TOOL
HANDLE
Figure 4 - Tool Use
GR30 User Manual ◄ 17

Advertisement

Table of Contents