3-13. Error Code H1-16 failure detection procedure

Checking device.
[U3802 :
SiI9437]
Check the power supply voltage. (ARC IC)
Check item(45).
Check the power supply voltage. :
Does the power supply voltage of the ARC IC [U3802] indicate the correct voltage (1.21V)?
The test points are as follows.
N3401
HDMI OUT
[MONITOR2]
1.2V
L3805
YES
Check item(46).
Check the power components [U3801] and the pattern on the sub-
strate.
If there is no problem, remove the ARC IC [U3802] from the sub-
strate and measure the voltage at the test point of
Is the power supply voltage correct (1.2V)?
Replace with a new device.
Recheck from
If it does not work, replace the PCB.
NO
Check the power supply voltage. :
check item
YES
NO
The power supply circuit is
faulty.
Replace the PCB.
check item (1).
Checking the reset waveform. (ARC IC)
Check item(47).
Checking the reset waveform :
Check the waveform.
Is the "RESET" waveform of the ARC IC [U3802] correct (like the
one shown in the diagram) when the power is turned on?
N3402
HDMI OUT
[MONITOR1]
R3805 : RESET
U3802
YES
(45).
ARC IC [U3802] is faulty.
Replace with a new device.
Recheck from
check item (1).
If it does not work, replace the PCB.
116
Examples of confirmation waveform
Voltage scale : 1.0V/div
Time scale : 20ms/div
NO
Check the reset circuit between
CPU [U6201] and ARC IC [U3802].
If there is no problem, the ARC IC
[U3802] is faulty.
Replace with a new device.