When the results of check item (72) are "00"
(Detection of HPD is not OK / Detection of RXSENSE is not OK )
Check the TMDS/HPD. (HDMI OUT1)
Check item(78).
Checking the HPD and RXSENSE. :
Does the test point near HDMI output terminal [N3401] indicate
(3.3V)?
Does the test point (HPD) near HDMI output terminal [N3401] indi-
cate "Hi(3-5V)"?
N3401
HDMI OUT
[MONITOR2]
HPD
YES
NO
Check for a short circuit in the TMDS/HPD line.
If there is no problem, the HDMI Tx [U3401] is faulty.
Replace with a new device.
HDMI Tx [U3401] is faulty.
Replace with a new device.
Recheck from
check item (4).
If it does not work, replace the PCB.