Crank Arms - Schwinn Airdyne AD2 Service Manual

Hide thumbs Also See for Airdyne AD2:
Table of Contents

Advertisement

Replacing the Crank Arms
Disconnect the data cable from the console before you service this machine.
Note: Your machine may not match the image. For reference only.
Tools required: pedal wrench, 4mm hex key, #2 Phillips screwdriver,
13mm socket and wrench
1.
Remove the Pedals. Refer to the "Replacing the Pedals"
procedure in this manual.
2.
Loosen and remove the Hardware (A1, A2) that attaches the
Crank Arm (A) to the Crank Cover (B). Discard the old Crank Arm
and hardware.
Note: Do not let the Star Washers (B1) on the Crank Cover fall
down inside the Shroud.
Installation is the reverse procedure.
3.
4.
Final Inspection
Inspect your machine to ensure that all hardware is tight and
components are properly assembled.
Do not use until the machine has been fully assembled and
inspected for correct performance in accordance with the
Owner's Manual.
B1
B
15
A2
A
A1
4mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents