Specifications; Measuring Head - Konica Minolta CR-400 Instruction Manual

Chroma meter
Hide thumbs Also See for CR-400:
Table of Contents

Advertisement

Specifications

<Measuring Head>
Name
Model
Illuminating/viewing system
Detector
Display range
Light source
Measurement time
Minimum measurement interval
Battery performance
Measurement/illumination area
Repeatability
Inter instrument agreement
Observer
Illuminant
Display
Tolerance judgment
Color system / Color space /
Colorimetric data
Languages
Storable data sets
Color difference target colors
Calibration channels
Display
Interface
Power source
Size
Weight
Operating temperature/
humidity range (*1)
Storage temperature/humidity range
Other
*1 Operating temperature/humidity range of products for North America: 5 to 40ºC, less than 80% relative humidity at 31ºC with no condensation
150
Chroma Meter Measuring Head
CR-400 Head
Diffuse illuminating/0º viewing
(speculer component included)
Silicone photo cells (6)
Y: 0.01 to 160.00% (reflectance)
Pulsed xenon lamp
1 sec.
3 sec.
Approx. 800 measurements
conditions)
φ 8/ φ 11
Within ∆E*ab0.07 standard deviation (when the white calibration plate was mea-
sured 30 times at intervals of 10 seconds)
∆E*ab: within 0.6
Average of 12 BCRA series II colors
*
Closely matches CIE 1931 Standard Observers: ( - x2λ, - yλ, - zλ)
*
C, D65
Chroma values, color difference values, color difference graphs,
*
PASS/WARN/FAIL display
*
Color difference tolerance (box tolerance and elliptical tolerance)
XYZ, Y x y, L*a*b*, Hunter Lab, L*C*h, Munsell (only illuminant C), CMC
(l:c), CIE1994, Lab99, LCh99, CIE2000, CIE WI-Tw (only illuminant D65),
WI ASTM E313 (only illuminant C), YI ASTM D1925 (only illuminant C),
YI ASTM E313 (only for illuminant C), User index (up to six can be
registered from computer)
*
Operating keys: English
LCD : English (default), German, French, Italian, Spanish, Japanese
1000 (measuring head and data processor save different data)
*
100
20 channels (ch00: white calibration, ch01 to ch19: user calibration)
Dot-matrix LCD with back light (15 chars x 9 lines + 1 line for icon display)
*
RS-232C compliant (for data processor/PC)
USB2.0 (When using the USB-Serial Converter Cable CR-A105, 2 m)
Baud rate: 4800, 9600, 19200 (bps), set at 9600 bps when shipped from factory
AAA alkaline or NiMH batteries x 4
AC adapter (AC-A305) AC100-240V
105(W) x 217(H) x 63(D)mm
Approx. 540g
(including 4 AAA size batteries and not including RS-232C
Converter
Cable)
0 to 40°C, relative humidity 85% or less
-20 to 40°C, relative humidity 85% or less
LCD back light ON/OFF function (when ON, back light stays ON for 30 seconds
after last key or measurement operation)
CR-410 Head
Wide-area Diffuse illuminating/0º view-
ing (specular component included)
(When using batteries under Konica Minolta's test
φ 50/ φ 53
∆E*ab: within 0.8
24-38VA 0.24-0.16A 50/60Hz
105(W) x 244(H) x 63(D)mm
Approx. 560g
(at 35ºC with no condensation)
(at 35ºC with no condensation)
cable, USB-Serial

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cr-410

Table of Contents