5167821-YTG-J-0518
Accessories (Continued)
Field Installed Accessories - Electric Heat
MODEL
VOLTAGE DESCRIPTION
2TP04510325
230
2TP04510346
460
2TP04510625
230
2TP04510646
460
2TP04510825
230
2TP04510846
460
2TP04510858
575
2TP04511525
230
2TP04511546
460
2TP04511558
575
2TP04512025
230
2TP04512046
460
2TP04512058
575
2TP04512325
230
2TP04512346
460
2TP04512358
575
Field Installed Accessories - Fresh Air
MODEL
VOLTAGE DESCRIPTION
1FA0413
All
1FA0414
All
1EH0408
All
2EC0401
All
2EC0402
All
2EE04717424
All
2EE04706924
All
2MD04703824
All
2MD04703924
All
2PE04704706
230
2PE04704746
460
2PE04704758
575
Field Installed Accessories - Controls
MODEL
VOLTAGE DESCRIPTION
2AP0401
All
2AQ04700524
All
2AQ04700624
All
2DF0402
All
2SH0401
All
2SD04700824
All
2SD04700924
All
2SD04701024
All
S1-YK-
All
MAP1810-0P
S1-MP-PRTKIT-
All
0P
10
3kW Electric Heat
6kW Electric Heat
9kW Electric Heat
15kW Electric Heat
20kW Electric Heat
24kW Electric Heat
Manual Outside Air Damper 0-35%, Downflow
Manual Outside Air Damper 0-100%, Downflow
Barometric Relief Kit for Power Exhaust, Horizontal
Application
Single Enthalpy Control
Dual Enthalpy Control (Includes 2 Sensors)
Economizer for Downflow, End Return Horizontal, or
ERV Applications. Includes FA Hood, Exhaust Hood w/
Baro Relief
Horizontal Economizer without Barometric Relief
Motorized Damper, Downflow without Barometric Relief
Motorized Damper, Horizontal without Barometric Relief
Power Exhaust 230V Downflow or Horizontal
Power Exhaust 460V Downflow or Horizontal
Power Exhaust 575V Downflow or Horizontal
Air Proving Switch
CO² Space Accessory
CO² Unit Accessory
Dirty Air Switch
Wall Mounted humidity sensor-For use with MagnaDry
Reheat or space humidity input to Smart Equipment™
board.
Smoke Detector for Supply
Smoke Detector for Return
Smoke Detector for Supply and Return
MAP (Mobile Access Portal) Gateway- For use with
Smart Equipment™ Control.
MAP (Mobile Access Portal) Gateway Kit- Replacement
MAP gateway protective case, lanyard and
communication cable. Use only to replace worn or
damaged components.
WHERE USED
All 42" Cabinet 3 Ton Models
All 42" Cabinet 3, 4 and 5 Ton Models
All 42" Cabinet 3, 4 and 5 Ton Models
All 42" Cabinet 3, 4 and 5 Ton Models
All 42" 4 and 5 Ton Models
All 42" Cabinet 5 Ton Models
WHERE USED
All Cabinets
All Cabinets
All Cabinets
All Cabinets
All Cabinets
All 42" Cabinets
All Cabinets
All Cabinets
All Cabinets
All Cabinets
All Cabinets
All Cabinets
WHERE USED
All Units
All Units
All Units
All Units
All Cabinets
All Gen 6 and greater units with 2" & 4" Filters
All Gen 6 and greater units with 2" & 4" Filters
All Gen 6 and greater units with 2" & 4" Filters
All Units
All Units