8. Low Oil Alarm: The red warning light will
illuminate and the engine will automatically shut
down if the oil level becomes too low. Add oil to
the correct level before re-starting the engine.
9. Engine Control Switch: When the switch is
momentarily depressed and held in the START
position, the electric starter motor engages and
starts the engine. Once the engine starts, release
the switch and it will automatically return to the
RUN position. Once started, the switch will
remain in the RUN position. To stop the engine,
move the switch to the STOP position.
10. ECO Throttle Switch: Move the switch to the
ON position when powering small resistive loads
such as a computer or electric light; the engine
speed will automatically be kept to a minimum,
thereby reducing fuel consumption and noise.
Select the OFF position when powering large
inductive loads such as an air conditioner or
electric pump; the engine speed will be kept
higher for maximum electrical starting power.
11. Frame Terminal: The frame terminal can be used
by a licensed electrician to earth the generator if
necessary.
12. Generator Reset Button: Press and hold down
this button to reset the generator's electrical
output when safe to do so after reducing the
applied load or rectifying the electrical fault that
has caused an overload trip.