Gov. Basic Menu (Governor Basic Setting) - FUTABA CGY760R Instruction Manual

Flybarless control gyro cgy760r gyro program box gpb-1
Hide thumbs Also See for CGY760R:
Table of Contents

Advertisement

G
B
OV.
the "
From 6/6
GOV. BASIC screen 1/6
(1) Governor: Governor active
Set the governor operation mode of CGY760R. The initial setting is
"ACT (active)" where , as the designation implies, the governor is active.
If you do not want to use governor, select "INH (Inhibit)" .
Setting: ACT (Active) / INH (Inhibit)
(2) Gear Ratio:
Input the main rotor gear ratio by pushing the [ /+] or [ /-] key to select
the desired working mode.
Setting ranges: 1.00 ~ 50.00t
M
ENU ( GOVERNOR BASIC SETTING )
ASIC
"
From the "SBUS2 rpm Slot"
of GOV. BASIC screen 6/6
Go to 2/6 from any cursor position
Notes:
• If the gear ratio is not properly set,
the set speed and actual engine
speed will be different.
• The gear ratio should be given in the
helicopter instruction manual. If the
helicopter instruction manual does
not give the gear ratio, calculate the
gear ratio as follows:
"
Note: When using the governor function, be sure
to make each setting of "GOV.BASIC".
Note: After completing the linkage of the throttle,
be sure to set the "Servo limit point setting" first,
and then set the other functions.
:
:
Initial setting: ACT
Initial value: 8.00t
Engine
pinion gear
N2
Carry values less than 1/1000 to the
60
" screen from
:
Rotor
main gear
N1
Gear ratio = N1/N2
next whole number.