UDM-0808-SIG Wiring and Connections
Serial Port - Default Communication Settings
Use hyper terminal with default serial settings to communicate with the UDM-0808-SIG (and UDM-RX02N):
Default Serial Settings
Baud Rate:
Data Bits:
Parity:
Stop Bits:
Flow Control:
DB9-to-RJ12 Adapter Cable Pinouts
The following table provides the pinout configuration for the DB9-to-RJ12
cable:
DB9-to-RJ12 Adapter Cable Pinouts
DB9 connector
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
CASCADE Ports
The CASCADE ports allow UDM-0808-SIG Hubs to be chained together to increase the number of outputs
which can be delivered to the end points. The CASCADE IN and OUT connectors on the UDM Hubs require a
UDM-EXP-02 Cascade Cable (FG-1402-71 - not included).
CASCADE 5-8 IN
CASCADE 5-8 OUT
CASCADE 1-4 IN
CASCADE 1-4 OUT
FIG. 10
Cascade 5-8, 1-4 Ports
The CASCADE (Out) ports can also be used to send audio to the UDM-ABB-8-SIG Signature Series Audio
Breakout Box (FG1402-60). Refer to the UDM-ABB-8-SIG Audio Breakout Box section on page 71 for
details.
10
115200
8
None
1
None
Function
Not used
Transmit Data
Receive Data
Data Set Ready
Signal Ground
Data Terminal Ready
Not Used
Not Used
Not Used
Refer to the Cascading Hubs section on page 77 for details on configuring cascaded Hubs.
UDM-0808-SIG, UDM-RX02N and UDM-ABB-8-SIG Operation /Reference Guide
(FG-RS01, not included)
Abbreviation
RJ12 connector
NC
TD or TX or TXD
Pin 2
RD or RX or RXD
Pin 3
DSR
Pin 1
GND
Pin 4, 5
DTR
Pin 6
NC
NC
NC
From source UDM Hub
(CASCADE OUT port)
To another UDM Hub or
UDM-ABB-8-SIG (CASCADE IN port)
From source UDM Hub
(CASCADE OUT port)
To another UDM Hub or
UDM-ABB-8-SIG (CASCADE IN port)
adapter