Specifications - Honeywell OELD Operating Instructions Manual

Smart junction box
Hide thumbs Also See for OELD:
Table of Contents

Advertisement

10 Specifications

Material
Weight
Dimensions
Cable entries
Termination
Storage Temperature
Operational temperature
Humidity
Display Information
Visual indication
Power supply
Interfaces
Environmental Protection IP66 / Type 4X(in accordance with NEMA 250)
Core Approvals
+flameproof versions only
OELD Specification
Marine-grade aluminum alloy or 316 stainless steel with 5-coat painted finish
Aluminum version 2.3 kg (5 lb), stainless steel version 5.0 kg (11 lb)
159 x 197 x 114 mm (6 ¼ x 7 ¾ x 4 ½ inch)
5 x M25 (ATEX/IECEx version) or 5 x ¾" NPT (cULus version). One reserved for sensor connection. 3
blanking plugs supplied for unused entries.
2 x pluggable rising-clamp type for connection to gas detector and field wiring. Accepts cable sizes of
0.5 to 2.5 mm², 12 to 28 AWG
-40 to +65 °C (-13 to 149 °F)
-40 to +65 °C (-40 to 149 °F)
-60 to +65 °C (-76 to 149 °F) (CU TR-Ex version only)
0 to 99% RH (non-condensing)
LCD module showing digital readout of sensor output, bar chart representation, units of measurement,
status icons for alarm, maintenance and active Bluetooth connection. Display units, range and gas
name, all configurable using the App.
Green/amber/red/blue multi-colour backlight to display for indication of detector and OELD status.
Green (normal) indication can be disabled via app.
18 to 32 Vdc (24 Vdc nominal), <2 W
Bluetooth® (BLE) non-intrusive connection to suitable mobile device running the OELD App. Range
up to 10 m (depends on mobile device and environmental conditions)
Internal RS-485 connection to Searchpoint Optima Plus or Searchline Excel via SHC-1 through the
protection device
EN 50270:2015 (EMC)
IEC/EN/UL/CSA 61010-1 (Electrical Safety)
10 Specifications