3. Reading the Upper and Lower byte of Compensated Flow Data Registers(D051h & D052h)
The first data after the initialization process is not the flow rate data. Disable this data.
I2C command: To read Compensated flow data register, it needs to set 2Ch (it
START
Slave Address
S
D8h (6Ch (7b)+ 0)
I2C command: Through Read Buffer 0(address:07h) and Read Buffer 1(address:08h),
START
Slave Address
S
D8h (6Ch (7b)+ 0)
D6F-PH MEMS Differential pressure Sensor User's Manual (A288)
means 2byte read) to interface configuration register (address:2h).
ACK
Access Address
A
00h
Serial Ctrl
you can read the 2byte of Compensated flow data.
ACK
Access Address
A
07h
Re-Start
Slave Address
RS
D9h (6Ch (7b)+ 1)
ACK
Reg Address H
A
D0h
ACK
STOP
2Ch
A
P
ACK
A
ACK
Read Data H
A
xxh
ACK
Reg Address L
A
51h
ACK
Read Data L
A
xxh
ACK
A
ACK
STOP
NA
P
22