Method 1 - Air gap with a waste tee or garbage disposal connection
Method 2 - High drain with a waste tee or garbage disposal connection
You must provide a method to attach the drain hose to the underside of the countertop.
18 in. (45.72 cm)

Electrical requirements

• This appliance must be supplied with 120V, 60 Hz, and it must be connected to its own, properly grounded branch
circuit that is protected by a 15 or 20 ampere circuit breaker or time delay fuse.
• Wiring must be two wire with ground.
• If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.
Warning:
Remove the house fuse or open the circuit breaker before beginning the installation. Do not use an extension
cord or adapter plug with this appliance.

GROUNDING INSTRUCTIONS

Grounding Instructions – Cable Direct
This appliance must be connected to a grounded metal, permanent wiring system, or an equipment grounding conductor
must be run with the circuit conductors and be connected to the equipment grounding terminal or lead on the appliance.
Grounding Instructions – Power Cord Models
This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electrical
shock by providing a path of least resistance for electric current. The plug must be plugged into an appropriate outlet that
is installed and grounded in accordance with local codes and ordinances.
WARNING
The improper connection of the equipment grounding conductor can result in a risk of electric shock. Check
with a qualified electrician or service representative if you are in doubt that the appliance is properly
grounded.
Direct Wire Method
• The cable must be routed as shown in Cabinet preparation and wire routing on page 8, and extend a minimum of 24 in.
(60.96 cm) from the rear wall.
• Use flexible, armored, or nonmetallic sheathed, copper wire with grounding wire that meets the wiring requirements
for your home and local codes and ordinances.
• Use a UL Listed/CSA Approved strain relief.
32 in. (81.28 cm) (min.)
www.insigniaproducts.com
NS-DWH2BS8 / NS-DWH2SS8 / NS-DWR2BS8 / NS-DWR2WH8
32 in. (81.28 cm) (min.)
18 in. (45.72 cm)