Powering Up the Switch
To power up the switch and verify hardware operation, follow these steps:
Step 1
Verify that sufficient PSUs and fan modules are installed.
Step 2
Plug the power cables into the power supplies and arrange the cables so that they cannot be accidentally pulled out.
Depending on the outlet receptacle on your power distribution unit, you may need the optional jumper power
Note
cord to connect the Cisco MDS 9148T Switch to your outlet receptacle.
Step 3
Connect the other end of the power cables to the site power outlets that have the required power specification.
Step 4
Ensure that the switch is adequately grounded, as described in the
Step 5
Connect a terminal device to the serial console port. For more information, see the
Step 6
If using Power On Automatic Provisioning (POAP), insert the USB stick with the required files into the USB port.
Step 7
Turn the site power outlet switches to On. The switch boots automatically.
Step 8
Listen for the fans; they should begin operating as soon as the switch is powered on.
Do not operate the switch without a functioning fan module, except briefly during the fan module replacement
Note
procedure. Cisco MDS 9000 Series Switches can operate for only a few minutes without any functioning fan
modules before they begin to overheat.
Step 9
Verify that the LED behavior is as follows when the switch has finished booting:
• Fan status LED is green.
• Both LEDs on each PSU are green.
• The switch status LED is green. If this LED is orange or red, it indicates that one or more environmental monitors
is reporting a problem.
• The Ethernet port link LEDs should not be On unless the cable is connected.
Note
Step 10
If a component is not operating properly, try removing and reinstalling it. If it still does not operate correctly, contact
your customer service representative for a replacement.
Note
If you purchased Cisco support through a Cisco reseller, contact the reseller directly. If you purchased support
directly from Cisco, contact
Step 11
Verify that the system software has booted and the switch has initialized without error messages. If any problems occur,
see the
Cisco MDS 9000 Series System Messages
representative.
Step 12
If not using POAP, manually complete the initial configuration of the switch via the automatically launched setup script
through the console connection.
Step 13
Complete the worksheets provided in Site Planning and Maintenance Records for future reference.
Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch Hardware Installation Guide
48
The LEDs for the Fibre Channel ports remain orange until the ports are enabled, and the LED for the
management port remains Off until the port is connected.
Cisco Technical
Grounding the Switch
Support.
Guide. If you cannot resolve an issue, contact your customer service
Connecting the Cisco MDS 9148T Switch
section.
Connecting the Console Port
section.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents