5.7

Eb (Communication error between the indoor PCB and display board)

Description: Indoor PCB does not receive feedback from Display board.
Recommended parts to prepare:
• Wiring mistake
• PCB faulty
• Display board malfunction
Troubleshooting and
repair:
Power off, then restart the
unit 2 minutes later.
Check the wirings and
Replace the indoor main PCB.
Is the problem solved?
The unit operates normally.
Page 68
Is it still displaying
the error code?
YES
connection.
Is it normal?
YES
YES
NO
The unit operates normally.
Correct the connection
NO
or replace the Wirings.
NO
Replace the Display board.