Operator Specifications

Usage Classification
Main AC Supply
System Operating Voltage
Accessory Power
Solar Power Max
Maximum Gate Weight
Minimum Gate Travel Distance
Maximum Gate Travel Distance
Maximum Gate Travel Speed
Maximum Daily Cycle Rate
Maximum Duty Cycle
Operating Temperature
Expansion Board
External Entrapment Protection Device Inputs (non-contact
and/or contact)
INTRODUCTION
Class I, II, III, & IV
120 Vac, 4 Amps (10 Amps including Accessory Outlets) OR 240 Vac, 2 Amps
When Optional Transformer Kit Model 3PHCONV is installed in the field, operator is rated
208/240/480/575 VAC, 4.8/4.2/2.1/1.7 A, 60 Hz, 1 PH
24 Vdc Transformer Run / Battery Backup
24 Vdc, 500mA max. for ON + SW (switched)
24 Vdc at 60 watts max.
1500 lbs. (680.4 kg)
4 feet (1.2 m)
50 feet (15.24 m)
1 foot/second
Continuous
Continuous
Without Heater: -20°C to 60°C (-4°F to 140°F)
With Optional Heater: -40°C to 60°C (-40°F to 140°F)
Provided
Main board - up to 2 close entrapment protection devices and 1 open entrapment
protection device.
Expansion board - up to 3 entrapment protection devices configurable to either close or
open and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU .