Sams Wiring With Relays Not Energized; Dual Gate Settings - Chamberlain CSL24UL Installation Manual

Elite series comercial dc vehicular slide gate operator
Table of Contents

Advertisement

SAMS wiring with relays not energized

Dual Gate Settings

NOTE: We recommend that all accessories and board configurations are set on the primary operator.
Main control board
FEATURE
PRIMARY OPERATOR
Timer-to-
Set the TTC dial to desired
Close
setting
Bi-Part
Bi-Part Delay: ON (will open
Delay
last and close first)
Switch
Tandem Mode: OFF
Synchronized Close: ON
Expansion board
FEATURE
PRIMARY OPERATOR
QUICK CLOSE Switch
ON
ANTI-TAIL Switch
ON
LOW BATT Switch
Battery Fail OPEN:
OPEN
Battery Fail CLOSE:
CLOSE
AC FAIL OPEN/BATT
OPEN
Switch
APPENDIX
SECONDARY OPERATOR
OFF
Bi-Part Delay: OFF (will open
first and close last)
Tandem Mode: OFF
Synchronized Close: ON
SECONDARY
OPERATOR
OFF
OFF
Battery Fail OPEN:
OPEN
Battery Fail CLOSE:
CLOSE
OPEN
Accessories
ACCESSORY
PRIMARY OPERATOR
Remote Controls
Program remote
controls 1 to 50 to the
primary operator.
LiftMaster Internet
Program to primary
Gateway
operator.
Garage and Gate
Program to primary
Monitor
operator.
48
SECONDARY
OPERATOR
Program remote
controls 51 to 100 to the
secondary operator

Hide quick links:

Advertisement

Table of Contents
loading