GENERAL DATA - RJNL MODELS
NOMINAL SIZES 3-5 TONS [10.6-17.6 kW]
Model RJNL- Series
1
Cooling Performance
Gross Cooling Capacity Btu [kW]
2
EER/SEER
Nominal CFM/ARI Rated CFM [L/s]
ARI Net Cooling Capacity Btu [kW]
Net Sensible Capacity Btu [kW]
Net Latent Capacity Btu [kW]
Net System Power kW
Heating Performance (Heat Pumps)
High Temp. Btuh [kW] Rating
System Power KW / COP
Low Temp. Btuh [kW] Rating
System Power KW / COP
HSPF (Btu/Watts-hr)
Compressor
No./Type
3
Outdoor Sound Rating (dB)
Outdoor Coil - Fin Type
Tube Type
Tube Size in. [mm] OD
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Indoor Coil - Fin Type
Tube Type
Tube Size in. [mm]
Face Area sq. ft. [sq. m]
Rows / FPI [FPcm]
Refrigerant Control
Drain Connection No./Size in. [mm]
Outdoor Fan - Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
CFM [L/s]
No. Motors/HP
Motor RPM
Indoor Fan - Type
No. Used/Diameter in. [mm]
Drive Type/No. Speeds
No. Motors
Motor HP
Motor RPM
Motor Frame Size
Filter - Type
Furnished
(NO.) Size Recommended in. [mm x mm x mm]
Refrigerant Charge Oz. [g]
Weights
Net Weight lbs. [kg]
Ship Weight lbs. [kg]
1. Cooling Performance is rated at 95° F ambient, 80° F entering dry bulb, 67° F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity
NOTES:
is net and includes the effect of fan motor heat. Units are suitable for operation to ±20% of nominal cfm. Units are certified in accordance with the Unitary Air Conditioner
Equipment certification program, which is based on ARI Standard 210/240 or 360.
2. EER and/or SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard
A036DL
A036DM
37,800 [11.08]
37,800 [11.08]
11.5/13
11.5/13
1200/1200 [566/566]
1200/1200 [566/566]
36,200 [10.61]
36,200 [10.61]
27,000 [7.91]
27,000 [7.91]
9,200 [2.7]
9,200 [2.7]
3.1
3.1
34,400 [10.08]
34,400 [10.08]
2.94/3.4
2.94/3.4
19,600 [5.74]
19,600 [5.74]
2.72/2.1
2.72/2.1
7.7
7.7
1/Copeland Scroll
1/Copeland Scroll
83
83
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
16.89 [1.57]
16.89 [1.57]
1 / 22 [9]
1 / 22 [9]
TX Valves
TX Valves
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
5.16 [0.48]
5.16 [0.48]
3 / 13 [5]
3 / 13 [5]
TX Valves
TX Valves
1/0.75 [19.5]
1/0.75 [19.5]
Propeller
Propeller
1/24 [609.6]
1/24 [609.6]
Direct/1
Direct/1
4000 [1888]
4000 [1888]
1 at 1/3 HP
1 at 1/3 HP
1075
1075
FC Centrifugal
FC Centrifugal
1/10x10 [254x254]
1/10x10 [254x254]
Belt/Variable
Belt/Variable
1
1
1/2
3/4
1725
1725
56
56
Disposable
Disposable
Yes
Yes
(2)1x25x16 [25x635x406]
(2)1x25x16 [25x635x406]
116 [3289]
116 [3289]
517 [235]
517 [235]
532 [241]
532 [241]
270.utdoor Sound Rating shown is tested in accordance with ARI Standard 270.
A036JK
A042CK
Continued ->
37,800 [11.08]
44,000 [12.89]
11.5/13
11.2/13
1200/1200 [566/566]
1400/1400 [661/661]
36,200 [10.61]
42,000 [12.31]
27,000 [7.91]
31,200 [9.14]
9,200 [2.7]
10,800 [3.16]
3.1
3.74
34,400 [10.08]
41,000 [12.01]
2.94/3.4
3.38/3.5
19,600 [5.74]
24,400 [7.15]
2.72/2.1
3.12/2.3
7.7
7.7
1/Copeland Scroll
1/Copeland Scroll
83
83
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
16.89 [1.57]
16.89 [1.57]
1 / 22 [9]
1 / 22 [9]
TX Valves
TX Valves
Louvered
Louvered
Rifled
Rifled
0.375 [9.5]
0.375 [9.5]
5.16 [0.48]
5.16 [0.48]
3 / 13 [5]
3 / 13 [5]
TX Valves
TX Valves
1/0.75 [19.5]
1/0.75 [19.5]
Propeller
Propeller
1/24 [609.6]
1/24 [609.6]
Direct/1
Direct/1
4000 [1888]
4000 [1888]
1 at 1/3 HP
1 at 1/3 HP
1075
1075
FC Centrifugal
FC Centrifugal
1/10x10 [254x254]
1/10x10 [254x254]
Direct/3
Direct/3
1
1
1/2
1/2
1075
1075
48
48
Disposable
Disposable
Yes
Yes
(2)1x25x16 [25x635x406]
(2)1x25x16 [25x635x406]
116 [3289]
120 [3402]
517 [235]
521 [236]
532 [241]
536 [243]
23