Basic Controller Programming

Programming Overview

The Controller can be programmed with various options for the operator.
The programming fi elds are defi ned as "functions" that have "options".
To make setup easier for the installer, the Controller's programming is
divided into two groups: basic and advanced. The basic programming
group contains the functions commonly used in most swing gate
installations. The advanced programming group contains functions less
commonly used (i.e. dual gate stagger delay, maximum run timer, etc.).

Entering Programming Mode

Enter programming mode by pressing the UP and DOWN buttons
together for one second. While in programming mode the PROGRAM
indicator will light.

Exiting Programming Mode

Exit programming mode at any time by pressing the UP and DOWN
buttons together. The Controller will automatically exit programming
mode after three minutes of inactivity.

Programming Keystrokes

(Typical Programming Method)
While in programming mode, press the UP or DOWN buttons to scroll
through the programming functions. When the desired function is
displayed press the ENTER button to display the currently set option for
the function. When an option is displayed, the decimal points are lit.
To change the option, press and hold the ENTER button for 1 second. To
indicate that an option is ready to be changed, the display will fl ash. While
the display is fl ashing, press the UP or DOWN button to display the other
options available for that function.
When the desired option is displayed, press the ENTER button to store
it into memory. To select another function, press ENTER, UP, or DOWN.

Left or Right Hand Operation

The function is not used with barrier gates.

Dual Gate Enable

The factory default is for single gate operation. For dual gate operation,
wire the two gate controllers together through the COMM LINK terminals
(see Page 19) and enable dual gate operation with this programming
step.

Auto Close Timer

The factory default turns off the Auto Close Timer. The timer can be set
from 1 to 59 seconds and from 1 to 9 minutes. When the Auto Close
Timer is set, after opening, the gate will wait for the length of the Auto
Close Timer then close automatically.

Run Alarm and Pre-start Alarm

The function is not used with barrier gates.
SG • SG-D Barrier Gate Operator Installation Guide
ENTERING
PROGRAMMING
SELECT
FUNCTION
UP
OR
DOWN
PRESS UP OR DOWN
TO SCROLL DISPLAY
THROUGH FUNCTIONS
PROGRAMMING
KEYSTROKES
FUNCTION
FUNCTION
"PM"
"RL"
SINGLE GATE
DUAL GATE
FUNCTION
FUNCTION
"RP"
"AC"
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
AUTO CLOSE
TIMER
- 11 -
DOWN
UP
AND
PRESS DOWN AND UP
PROGRAM INDICATOR
BUTTONS TOGETHER
WILL LIGHT WHEN SYSTEM
FOR ONE SECOND
IS IN PROGRAM MODE
CURRENTLY
OPTION READY
SET OPTION
TO CHANGE
UP
OR
ENTER
ENTER
DOWN
PRESS ENTER FOR
ONE SECOND TO
SELECT OPTION
PRESS UP
(THE DISPLAY
OR DOWN
WILL FLASH)
TO CHANGE
OPTION
PRESS ENTER TO
DISPLAY CURRENTLY
SET OPTION
OPTIONS
SINGLE GATE INSTALLATION
DUAL GATE INSTALLATION
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
OPTIONS
AUTO CLOSE TIMER DISABLED
SET TIMER VALUE
1 TO 59 SECONDS
SET TIMER VALUE
1 TO 9 MINUTES
PROGRAM
INDICATOR
CHOOSE
OPTION
SELECT
OPTION
STORED
FUNCTION
ENTER
ENTER
OR
PRESS ENTER
UP
TO STORE
OPTION
OR
DOWN
PRESS UP, DOWN
OR ENTER SELECT
NEXT FUNCTION
P1277 Revision X2 8-11-2011

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sg-d

Table of Contents