4-1 ADJUSTMENT CONDITIONS AND PRECAUTIONS

4.1.1. Approximately 30 minutes should be allowed for warm up before proceeding.
4.1.2. Adjustments should be undertaken only on those necessary elements since most of them have
been carefully preset at the factory.

4-2 MAIN ADJUSTMENTS

NO.
1.
14V ADJ
2.
B + ADJ
3.
SCREEN ADJ
4.
FOCUS ADJ
5.
ABL ADJ
6.
FUNCTION ADJ

4-3 ADJUSTMENT METHOD

4.3.1. 14V, B + & HV voltage adjustment:
A. Chroma-2000 Signal generator or PC equivalent set mode 1, VGA 640X480 pattern 1.0.
B. Connect a DC Volt meter between TP901 and ground, then adjust VR903to be 14VDC.
C. Connect a DC Volt meter between TP902 and ground, then adjust VR902 to be 64
4.3.2. Factory preset Timings Adjustment:
A. Press MENU Key to show OSD window press Up or Down Key to switch the functional controls.
B. Press the Up Key to select the "ZOOM" function, then press the MENU Key. While do not
release the MENU Key until the OSD window changed to the Factory preset window.
C. The Factory preset window contains the following functional controls. Select one of the control.
Then press the Up/Down Key to adjust its value for the optimum picture.

4. ADJUSTMENT

FUNCTION
-MENU
-UP
-DOWN
-EXIT
-RECALL
LOCATION
PCB - MAIN
PCB - MAIN
FLY BACK TRANS
FLY BACK TRANS
PCB - MAIN
PCB - MAIN
PCB - MAIN
PCB - MAIN
PCB - MAIN
PCB - MAIN
7
DESIGNATION
VR903
VR902
T402 SCREEN VR
T402 FOCUS VR1&VR2
AB in factory OSD
<SW104>
SW104
<SW103>
SW103
(SW103)
VDC.