Installation

13.1 Mechanical Installation

Installing the OP3
Insert the OP3 from the front into the prepared cutout. To do this, proceed as
follows:
1. Remove three screws on the rear of the housing (Figure 13-1).
2. Pull the two sections of the housing carefully apart.
3. Stick the three enclosed self-adhesive spacing rings onto the appropriate
4. Push the enclosed seal over the front part of the housing.
5. Push the parts of the housing on both sides of the mounting cutout back
6. Screw both sections of the housing together with three screws. Make sure
3
Figure 13-1 Rear of the OP3 Showing Screw Connections
After mounting, the contrast control should remain accessible for adjusting
the contrast of the display.
The whole area of the OP3 is covered with a protective foil. You can remove
the foil once the OP3 has been installed. OP3 functionality is also guaranteed
with the foil left on, however; further, the foil protects the device from
contamination.
13-2
screw drill holes in the interior of the housing back panel:
Use
No ring
One ring
Two rings
over one another.
the gasket on the front panel fits properly.
2
1
1
for Metal Thickness
To 0.3 mm
0.3 mm to 1,5 mm
1.5 mm to 4 mm
1
2
3
1
Screws
Contrast
control
Interface
Operator Panel OP3