Troubleshooting; Specifications - Interlogix 600-1046-95 Installation Instructions

Oem transceiver module with crystal transmitter

Advertisement

Figure 2. Installing the circuit board
600-1029 enclosure
Top latches
OEM transceiver
2 mm power jack
Terminal block
Daughter board
LEDs
Bottom latch
4.
Connect DC power to the OEM transceiver module using
2 mm power jacks (center positive) or connect flyleads to
the terminal block as labeled on the board.
LED operation
Table 1
shows the LED indications for the OEM transceiver
module
Table 1: OEM transceiver module LED indications
Indication
Powered up
Communication with daughter board
Valid packet received

Troubleshooting

The following table gives troubleshooting suggestions for the
OEM transceiver module.
Table 2: OEM transceiver module troubleshooting
Problem
OEM transceiver module's green
and red LEDs are off
OEM receiver module's green LED
is on and the red LED is off

Specifications

Model
600-1046-95
Frequency
319.5 MHz
Compatibility
All 319.5 MHz sensors and 319.5 MHz
receivers
2
Antenna shrouds
Green LED
Red LED
On
Off
On
Flashing
One flash off
Off or flashing
Action
1. Check that the transformer
is plugged in.
2. Check the transformer to
module wiring.
Check the daughter board
mounting.
Current required (without daughter board)
Typical
45mA
Maximum
100mA
Voltage
8 to 15 VDC
Wireless range
1,000 feet (305 m) open air
Operating temperature
32 to 120°F (0 to 49°C)
Storage temperature
-30 to 140°F (-34 to 60°C)
Maximum relative
90% noncondensing
humidity
Dimensions
3.2 x 4.6 x 0.6 inches (8.1 x 11.7 x 1.5 cm)
Features
Antenna tamper, jam detect, wall tamper,
cover tamper
Optional items:
Enclosure
600-1029
USB daughter board
59-873
Repeater daughter
600-1031
board
Stand-off
40-262
Regulatory information
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943,
USA
FCC compliance
This device complies with FCC Rules Part 15.
Operation is subject to the following two
conditions:
1. This device may not cause harmful
interference.
2. This device must accept any interference that
may be received, including interference that may
cause undesired operation.
Changes or modifications not expressly approved
by UTC Fire & Security can void the user's
authority to operate the equipment.
FCC ID: B4Z-903-TCVR
IC: 867A-903-TCVR
California code
This product cannot be sold in the state of
California if used to receive fire signals (per
section 208-g, Chapter 1.5 Construction Materials
and Equipment Listings, Title 19, California Code
of Regulations
(http://osfm.fire.ca.gov/pdf/fireengineering/bml/t-
19.pdf)).
Contact information
For contact information, see www.utcfireandsecurity.com or
www.interlogix.com.
For technical support, toll-free: 888.437.3287 in the US
including Alaska, Hawaii, Puerto Rico, and Canada. Outside
the tool-free area, contact your dealer.
Copyright © 2011 Interlogix, a UTC Fire & Security Company.
All rights reserved.
OEM Transceiver Module with Crystal Transmitter Installation Instructions

Advertisement

loading