E. Reverse the Flue Collar
Tools Required: Phillips head screwdriver.
The flue collar is reversible for either a top or rear venting
installation. The appliance is shipped with the flue collar in
the top vent position.
Converting Collar For Rear Vent Installation
1. Remove (4) #10 X 1/2" phillips screws from the rear heat
shield. Remove heat shield. Figure 5.11.
2. Remove (2) 1/4-20 X 5/8" button head screws from the
flue collar. Remove flue collar. Figure 5.11.
3. Turn flue collar to horizontal position. Inspect rope gasket
located on the rear cast housing to ensure a leak free seal.
Re-install flue collar. Figure 5.12.
Note: The rear heat shield is not used on a rear vent
conversion.
Figure 5.11
Figure 5.12
20
(If necessary)
Flue Collar
Flue Collar
Heat Shield
Flue Collar
Vermont Castings • Intrepid FlexBurn
F. Outside Air Kit Installation
A source of air (oxygen) is necessary in order for combustion
to take place. Whatever combustion air is consumed by the
fire must be replaced. Air is replaced via air leakage around
windows and under doors. In homes that have tightly sealed
doors and windows, an outside air source is needed. An
optional Outside Air Kit is available.
Included in 0003265: Air Duct, (1) Hose Clamp, Pipe Elbow,
and fasteners
Items Needed for Installation (not supplied)
• Phillips head screw driver
• Silicone sealant
• Drills and saws necessary for cutting holes through
the wall or flooring in your home.
1. Remove all materials from packing box.
2. Using a #2 Phillips screw driver attach the flex adapter to
the appliance using 4 screws. Figure 5.13 & 5.14.
3. Floor & Rear Installation: Cut a 3" (76 mm) hole in outside
wall or floor to accommodate outside air piping. Use 3"
(76 mm) aluminum metal flex or rigid piping to directly
connect outside air to appliance intake. Use the supplied
termination cap with a rodent screen. Seal between the
wall (or floor) and the pipe with silicone to prevent moisture
penetration.
Figure 5.13 - Rear Installation
Installation Manual_R2 • 2018 - ___ • 07/18
®
3-90-30007345i