Convection Fan Motor; Damper Assembly - GE JK3800DH1BB Technical Service Manual

Combination wall oven
Hide thumbs Also See for JK3800DH1BB:
Table of Contents

Advertisement

Convection Fan Motor

The convection fan motor wire leads have locking
tabs that must be depressed to be disconnected.
To remove each wire from the fan motor, depress
the clip using a small blade screwdriver and pull the
The outer convection fan must be removed before
removing the motor. The outer convection fan is
held in place by a 7 mm nut, lockwasher, spacer and
Front View of Outer Convection Fan
The convection fan motor is held in place by Phillips
head screws .

Damper Assembly

The damper assembly is on the top right side of
the oven cavity. When the damper door is closed,
moisture is retained in the oven cavity. When the
damper door is open, moisture is released, allowing
food to be more crisp. The damper is open for
microwave operation and closed for all other
operations.
The outer cover must be removed to access or
observe operation of the damper assembly. (See the
Removing Upper Oven section in this guide.)
The damper assembly is held in place by two
pins and three Phillips head screws that attach
the damper assembly to the oven chassis. When
removing, move the damper assembly inward to
disengage the two pins from the vent tube.
– 48 –

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents