Samsung AM18B1C09 Owner's Instructions & Installation Manual

Samsung AM18B1C09 Owner's Instructions & Installation Manual

Multi-split type room air conditioner
Hide thumbs Also See for AM18B1C09:

Advertisement

MULTI-SPLIT TYPE ROOM AIR CONDITIONER
ACONDICIONADOR DE AIRE DOMÉSTICO SISTEMA MULTI SPLIT
E S F
DB98-05640A(2)
CLIMATISEUR DE TYPE MULTIPLE
OWNER'S INSTRUCTIONS &

INSTALLATION MANUAL

MANUAL DE INSTRUCCIONES &
MANUAL DE INSTALACIÓN
MANUEL D'UTILISATION &
MANUEL D'INSTALLATION
Indoor Unit
AM18B1C09
AM26B1C13
AM27B1C07
AM27B1C13
( Refroidissement )
Outdoor Unit
UM18B1C2
UM26B1C2
UM27B1C3
( Cool )
( Refrigeración )

Advertisement

Table of Contents
loading

Summary of Contents for Samsung AM18B1C09

  • Page 1: Installation Manual

    OWNER’S INSTRUCTIONS & INSTALLATION MANUAL MANUAL DE INSTRUCCIONES & MANUAL DE INSTALACIÓN MANUEL D’UTILISATION & MANUEL D’INSTALLATION Indoor Unit Outdoor Unit AM18B1C09 UM18B1C2 AM26B1C13 UM26B1C2 AM27B1C07 UM27B1C3 AM27B1C13 MULTI-SPLIT TYPE ROOM AIR CONDITIONER ( Cool ) ACONDICIONADOR DE AIRE DOMÉSTICO SISTEMA MULTI SPLIT ( Refrigeración )
  • Page 2: Safety Precautions

    Safety Precautions The following safety precautions must be taken when using your air conditioner. Make sure that the indoor unit is correctly ventilated at all times; do NOT place clothing or other materials over it. NEVER spill liquid of any kind into the indoor unit. Should this happen, switch off the breaker used for your air conditioner and contact your installation specialist.
  • Page 3: Table Of Contents

    Contents REPARING YOUR AIR CONDITIONER Safety Precautions ........2 View of the Unit .
  • Page 4: View Of The Unit

    View of the Unit The design and shape are subject to change according to the model. Indoor Unit Air Inlet Air flow blades (outlet) Air filter (under the grille) Timer indicator Remote Control Sensor SAVING indicator STANDARD indicator SILENCE indicator NATURE indicator POWER indicator On/Off &...
  • Page 5 Outdoor Unit UM18B1C2 Air Inlet(Rear) Air Outlet Connection Valve Outdoor Unit UM26B1C2 Air Inlet(Rear) Air Outlet Connection Valve Outdoor Unit UM27B1C3 Air Inlet(Rear) Air Outlet Connection Valve...
  • Page 6: Remote Control-Buttons And Display

    Remote Control - Buttons and Display Remote control transmission indicator Mode selection button Operating mode (AUTO, COOL, DRY, FAN) AUTO, COOL, DRY, FAN) Temperature adjustment Temperature setting buttons Turbo mode Turbo/Sleep mode Sleep mode selection button Fan speed Fan speed adjustment button Air flow direction Swing button...
  • Page 7: Getting Started

    etting Started You have just purchased a split type air conditioner and it has been installed by your installation specialist. Your Owner’s Instructions contains valuable information on using your air conditioner. Please take the time to read it as it will help you take full advantage of the unit’s features.
  • Page 8: Inserting The Remote Control Batteries

    Inserting the Remote Control Batteries You must insert or replace the remote control batteries when : You purchase the air conditioner The remote control does not work correctly Use two AAA, LR03 1.5V batteries. Do not use old batteries or different kinds of batteries together. Batteries may be completely discharged after 12 months, even if they have not actually been used.
  • Page 9: Way Function

    5 Way Function You can select the 5 Way function with operating mode of the air conditioner for more comfortable circumstances. You can use the 5 Way function with the indoor unit as well as the remote control. Thus, you can use this function even though you have lost your remote control.
  • Page 10: Selecting The Automatic Operating Mode

    Selecting the Automatic Operating Mode You can start the air conditioner in Automatic mode from your remote control. In the Automatic mode, the standard temperature and the optimum fan speed is selected automatically. You can adjust the standard temperature but not the fan speed. If necessary, press the (On/Off) button.
  • Page 11: Cooling Your Room

    Cooling Your Room You must select the Cool mode if you wish to adjust the: Cooling temperature Fan speed when cooling If necessary, press the (On/Off) button. Result: The 5 Way indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 12: Changing The Room Temperature Quickly

    Changing the Room Temperature Quickly The Turbo cooling function is used to cool your room as quickly as possible. You have just come home and find that the room is very hot. You wish to cool it down as quickly as possible. The Turbo function operates for 30 minutes with the maximum settings before returning automatically to the mode and temperature previously selected.
  • Page 13: Removing Excess Humidity

    Removing Excess Humidity If the atmosphere in your room is very humid or damp, you can remove excess humidity without lowering the room temperature too much. If necessary, press the (On/Off) button. Result: The 5 Way indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 14: Airing Your Room

    Airing Your Room If the atmosphere in your room is stale, you can air the room using the Fan feature. If necessary, press the (On/Off) button. Result: The 5 Way indicator on the indoor unit lights up. The air conditioner starts up in the mode selected when the unit was last used.
  • Page 15: Adjusting The Air Flow Direction Vertically

    Adjusting the Air Flow Direction Vertically Depending on the position of the indoor unit on the wall of your room, you can adjust the position of the outer air flow blade on the bottom of the unit, thus increasing the efficiency of the air conditioner. Press the SWING button one or more times as required.
  • Page 16: Setting The On Timer

    Setting the On Timer The On Timer enables you to switch on the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the ON TIMER button one or more times until the required time is displayed.
  • Page 17: Setting The Off Timer

    Setting the Off Timer The Off Timer enables you to switch off the air conditioner automatically after a given period of time. You can set the period of time from 30 minutes to 24 hours. To set the operating time, press the OFF TIMER button one or more times until the required time is displayed.
  • Page 18: Setting The Sleep Timer

    Setting the Sleep Timer The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of six hours. If you wish to switch the unit off at a specific time, refer to page 17.
  • Page 19: Operating Recommendations

    Operating Recommendations Here are a few recommendations that you should follow when using your air conditioner. Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, you must press the (ON/OFF) button to restart it.
  • Page 20: Temperature And Humidity Ranges

    Temperature and Humidity Ranges The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... Then... High temperatures The automatic protection feature may be triggered and the air conditioner stopped.
  • Page 21: Cleaning Your Air Conditioner

    Cleaning Your Air Conditioner To get the best possible use out of your air conditioner, you must clean it regularly to remove the dust that accumulates on the air filter. Before cleaning your air conditioner, ensure that you IMPORTANT have switched off the breaker used for the unit. Open the front grille by lifting the tabs on the lower right and left sides of the indoor unit.
  • Page 22: Solving Common Problems

    Solving Common Problems Before contacting the after-sales service, perform the following simple checks. They may save you the time and expense of an unnecessary call. Problem Explanation/Solution The air conditioner does not Check that the breaker used for the air conditioner is switched on. operate at all Check that the 5 Way indicator on the indoor unit is on;...
  • Page 23: Installing A Filter (Option)

    Installing a Filter (Option) The air conditioner can be fitted with a deodorizing and Bio-Pure filter to remove minute dust particles or odours. The service life of the filter is approximately three months depending on the time during which the air conditioner is used. Remove the vinyl packing from the filter.
  • Page 24: Technical Specifications

    Technical Specifications Indoor unit Outdoor unit Indoor unit Outdoor unit MODEL AM18B1C09 UM18B1C2 AM26B1C13 UM26B1C2 2 Comp + 2 Room 2 Comp + 2 Room Type Btu/h Capacity Cooling Performance A/B-Unit : 9000 A/B-Unit : 12500 Ratings SEER 10.0 10.0...
  • Page 25 Indoor unit Indoor unit Outdoor unit MODEL AM27B1C07 AM27B1C13 UM27B1C3 2 Comp + 3 Room Type Btu/h Performance Capacity Cooling A-Unit : 13000, B/C-Unit : 7000 Ratings SEER 10.0 Pts/h Moisture Removal Air FLOW(Cooling, HIGH) Sound Rating-Outdoor The number of operation 1 Unit operation 2 Unit operation 3 Unit operation...
  • Page 26 NSTALLATION ANUAL...
  • Page 27 Contents REPARING THE NSTALLATION Deciding on Where to Install the Air Conditioner ... 28 Air Conditioner and Accessories ..... . . 32 NSTALLING THE NDOOR Fixing the Installation Plate .
  • Page 28: Preparing The Installation

    REPARING THE NSTALLATION Deciding on Where to Install the Air Conditioner When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account. General Do NOT install the air conditioner in a location where it will come into contact with the following elements: Combustible gases Saline air Machine oil...
  • Page 29 REPARING THE NSTALLATION 18,000Btu/h Power supply Indoor unit Outdoor unit Ø, V, Hz AM18B1C09 UM18B1C2 1,208-230~,60 Respect the clearances and maximum lengths indicated in the diagram below when installing the unit. B-unit 9,000 Btu/h 25 mm (1 inch) or more...
  • Page 30 REPARING THE NSTALLATION Deciding on Where to Install the Air Conditioner (cont.) 26,000Btu/h Power supply Indoor unit Outdoor unit Ø, V, Hz AM26B1C13 UM26B1C2 1,208-230~,60 Respect the clearances and maximum lengths indicated in the diagram below when installing the unit. B-unit 12,500 Btu/h 25 mm (1 inch)
  • Page 31 REPARING THE NSTALLATION 27,000Btu/h Power supply Indoor unit Outdoor unit Ø, V, Hz AM27B1C07 UM27B1C3 1,208-230~,60 AM27B1C13 Respect the clearances and maximum lengths indicated in the diagram below when installing the unit. C-unit 7,000 Btu/h B-unit 7,000 Btu/h 25 mm (1 inch) or more A-unit 13,000 Btu/h...
  • Page 32: Air Conditioner And Accessories

    REPARING THE NSTALLATION Air Conditioner and Accessories The following accessories are supplied with the air conditioner. The quantities are indicated in parentheses. Accessories in the Indoor Unit Case Installation Plate (1) Remote Control (1) Batteries for Owner’s Instruction Remote Control (2) Booklet &...
  • Page 33: Installing The Indoor Unit

    NSTALLING THE NDOOR Fixing the Installation Plate Before fixing the installation plate to a wall or window frame, you must determine the position of the 65mm( inch) hole through which the cable, piping and hose pass to connect the indoor unit up to the outdoor unit.
  • Page 34: Purging The Unit

    REPARING THE NSTALLATION Purging the Unit On delivery, the indoor unit is loaded with an inert gas. All this gas must therefore be purged before connecting the assembly piping. To purge the inert gas, proceed as follows. Unscrew the caps at the end of each pipe. Result: All inert gas escapes from the indoor unit.
  • Page 35: Connecting The Assembly Cable

    NSTALLING THE NDOOR Connecting the Assembly Cable The outdoor unit is powered from the indoor unit via the assembly cable. If the outdoor unit is more than 5m(16ft. 5in) away from the indoor unit, the cable must first be extended to a maximum of 15m(49ft. 3in). Extend the assembly cable if necessary.
  • Page 36 NSTALLING THE NDOOR Connecting the Assembly Cable (cont.) Detach the control box from the indoor unit. Install the conduit kit. (The conduit kit is optional) Pass the assembly cable through the rear of the indoor unit and connect the Control Box assembly cable to terminals as shown in the figure.
  • Page 37: Installing And Connecting The Indoor Unit Drain Hose

    NSTALLING THE NDOOR Installing and Connecting the Indoor Unit Drain Hose Care must be taken when installing the drain hose for the indoor unit to ensure that any condensation water is correctly drained outside. When passing the drain hose through the 65mm( inch) hole drilled in the wall, check that none of the following situations occur.
  • Page 38: Installing And Connecting The Indoor Unit Assembly Piping

    NSTALLING THE NDOOR Installing and Connecting the Indoor Unit Assembly Piping There are two refrigerant pipes of different diameters: A smaller one for the liquid refrigerant A larger one for the gas refrigerant A short length of piping is already fitted to the air conditioner. You must extend this piping using assembly piping (optionally supplied).
  • Page 39: Cutting/Extending The Piping

    NSTALLING THE NDOOR Cutting/Extending the Piping 5 metres(16ft. 5in) of piping is supplied with the air conditioner(Optional). This length can if necessary be: Extended to a maximum of 15m(49ft. 3in) Shortened as required If more than 5m(16ft. 5in) of piping is required: The assembly cable must also be extended Refrigerant must be added to the circuit by an approved installer;...
  • Page 40: Connecting The Cables To The Outdoor Unit

    NSTALLING THE NDOOR Connecting the Cables to the Outdoor Unit (cont.) One electric cable must be connected to the outdoor unit: The assembly cable connecting the indoor unit to the outdoor unit UM18B1C2 Remove the terminal board cover on the side of the outdoor unit. Connect the assembly cable to terminals as shown in the figure.
  • Page 41 NSTALLING THE UTDOOR 18/26 Outdoor unit Terminal block Earth terminal Circuit Breaker (Main Power supply cable) Earth terminal Earth terminal Assembly cable Earth terminal Earth terminal Indoor unit A-unit B-unit Terminal block Outdoor unit Earth terminal Circuit Breaker (Main Power supply cable) Earth 1 2 3 1 2 3...
  • Page 42: Auxillary Circuit Breaker

    The supply voltage must be the same as the rated voltage of the air conditioner. Prepare the power souce for exclusive use with the air conditioner. Use 20 amperes time delay fuse or circuit breaker. AM27B1C07 AM26B1C13 MODEL AM18B1C09 AM27B1C13 Power supply 208-230V~/60Hz Power cable 3G AWG 14 Assembly cable 4G AWG 16 11.4A...
  • Page 43: Checking Correct Earthing

    NSTALLING THE UTDOOR Checking Correct Earthing If the power distribution circuit does not have an earth or the earth does not comply with specifications, an earthing electrode must be installed. The corresponding accessories are not supplied with the air conditioner. Select an earthing electrode that complies with the specifications given in Carbon Steel...
  • Page 44: Fixing The Unit In Position

    NSTALLING THE UTDOOR Fixing the Unit in Position The outdoor unit must be installed on a rigid and stable base to avoid any increase in the noise level and vibration, particularly if the outdoor unit is to be installed close to a neighbour.
  • Page 45: Completing The Installation

    OMPLETING THE NSTALLATION Connecting Up and Purging the Circuit The outdoor unit is loaded with sufficient R22 refrigerant for 5m(16ft. 5in) of piping. The air in the indoor unit and in the pipe must be purged. If air remains in the refrigeration pipes, it will affect the compressor, reduce to cooling capacity and could lead to a malfunction.
  • Page 46: Performing Leak Tests

    OMPLETING THE NSTALLATION Performing Leak Tests Before completing the installation (insulation of the cables, hose and piping and fixing of the indoor unit to the installation plate), you must check that there are no gas leaks. To check for gas leaks on the... Then, using a leak detector, check the...
  • Page 47: Placing The Indoor Unit In Position

    OMPLETING THE NSTALLATION Placing the Indoor Unit in Position Once you have checked that there are no leaks in the system, you can insulate the piping, hose and cables and place the indoor unit on the installation plate. To avoid condensation problems, place heat-resistant polyethylene foam separately around each refrigerant pipe in the lower part of the indoor unit.
  • Page 48: Checking And Testing Operations

    OMPLETING THE NSTALLATION Checking and Testing Operations To complete the installation, perform the following checks and tests to ensure that the air conditioner is operating correctly. Review all the following elements in the installation: Installation site strength Piping connection tightness to detect any gas leakages Connection wiring Heat-resistant insulation of the piping Drainage...
  • Page 49: Explaining Operations To The Owner

    OMPLETING THE NSTALLATION Explaining Operations to the Owner Before leaving the premises on which you have installed the air conditioner, you should explain the following operations to the owner, making reference to the appropriate pages in the owner’s instruction booklet. How to start and stop the air conditioner.
  • Page 50 THIS AIR CONDITIONER IS MANUFACTURED BY: ESTE AIRE ACONDICIONADO HA SIDO FABRICADO POR: CE CLIMATISEUR EST FABRIQUE PAR: ELECTRONICS Printed in Korea...