Installing And Connecting The Indoor Unit Drain Hose - Samsung AD18B1C09 Owner's Instructions & Installation Manual

Multi-split type room air conditioner ( cool and heat )
Hide thumbs Also See for AD18B1C09:
Table of Contents

Advertisement

Installing and Connecting the Indoor Unit Drain Hose

Care must be taken when installing the drain hose for the indoor unit to ensure that any
condensation water is correctly drained outside. When passing the drain hose through
the 65mm(
9
inch) hole drilled in the wall, check that none of the following situations occur.
2
16
The hose must
The end of the drain
NOT slope
hose must NOT be
upwards.
placed in water.
To install the drain hose, proceed as follows.
1
If necessary, connect the 2m(6ft. 7in) extension to the drain hose.
2
If you are using the extension, insulate the inside part of the extension
drain hose with a shield.
3
Pass the drain hose under the refrigerant piping, taking care to keep the
drain hose tight.
4
Pass the drain hose through the hole in the wall, making sure that it is
sloping downwards, as shown in the illustrations above.
The hose will be fixed permanently into position once the
whole installation has been tested for gas leaks; refer to
page 46 for further details.
Do NOT bend the
Keep a clearance of at
hose in different
least 5cm(2inch)
directions.
between the end of the
hose and the ground.
I
I
NSTALLING THE
NDOOR
5cm
(2inch)
Ditch
less
Do NOT place the
end of the drain hose
in a hollow.
Shield
Drain hose
Extension drain hose
U
NIT
37
E-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ad26b1e3Ad26b1c13Ud18b1c2Ud26b1c2Am26b1(b2)c13

Table of Contents