I
I
U
NSTALLING THE
NDOOR
NIT
Connecting the Assembly Cable (cont.)
Control Box
A
B
The conduit kit is optional(A and B).
Control Box
C
E
36
E-
5
Detach the control box from the indoor unit.
6
Install the conduit kit. (The conduit kit is optional)
7
Pass the assembly cable through the rear of the indoor unit and connect the
assembly cable to terminals as shown in the figure.
8
Pass the other end of the cable through the 65mm(
wall.
9
Reinstall the control box, then tighten the C screw.
10
Install the D terminal block cover, tightening the E screws.
11
Replace the front panel, carefully tightening the screws.
12
Reinstall the front grille.
13
For further details on how to plug the other end of the assembly cable into
the outdoor unit, refer to page 40.
D
Terminal
block
cover
Each wire is labelled with the corresponding terminal number.
The C screw is provided with this manual.
The D terminal block cover and E screws are provided with this manual.
Indoor
unit
1 2
3
1
2
3
Outdoor
unit
A1 A2 A3
Earth terminal
9
inch) hole in the
2
16
Earth
E
terminal
E
E