MIL-STD Ratings

Standard
MIL-STD 901D
MIL-STD 461
DOD-STD 1399
MIL-STD 1399 (Section 300B)
Section 6.3

EMC and Environmental Type Tests

The RUGGEDCOM MX5000 has passed the following EMC and environmental tests.
IEC 61850-3 EMC Type Tests
Test
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
38
Magnetic Field (DC Magnetic Exposure)
Standards for Shipboard Systems
Description
ESD
Radiated RFI
Burst (Fast Transient)
Surge
Induced (Conducted) RFI
Magnetic Field
Description
Shock (Hard-Mounted)
EMI
Electrical Power Interface
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal ports
DC Power ports
AC Power ports
Earth ground ports
Signal ports
DC Power ports
AC Power ports
Signal ports
D.C Power ports
AC Power ports
Earth ground ports
Enclosure Ports
RUGGEDCOM MX5000
Installation Guide
Comments
Approved
Approved
Approved
Approved
Test Levels
+/- 8 kV
+/- 15 kV
20 V/m
+/- 4 kV @ 2.5 kHz
+/- 4 kV
+/- 4 kV
+/- 4 kV
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
+/- 2 kV line-to-earth,
+/- 1 kV line-to-line
+/- 4 kV line-to-earth,
+/- 2 kV line-to-line
10 V
10V
10V
10V
100 A/m
1000 A/m for 1 s
MIL-STD Ratings
Severity
Levels
4
4
a
Note
a
Note
4
4
4
4
3
4
3
3
3
3
5