Chapter 2
Installing the Device
Figure 10: DC Terminal Block Wiring
1. Live Terminal    2. Ground Terminal    3. Neutral Terminal
2.
Connect the negative wire from the power source to the neutral terminal on the terminal block.
IMPORTANT!
If the ground terminals are not connected to safety Earth, the chassis ground connection must be
connected. For more information, refer to
3.
Using a braided wire or other appropriate grounding wire, connect the ground terminal to the chassis ground
connection. The ground terminal is used as the ground conductor for all surge and transient suppression
circuitry internal to the unit.
4.
Connect the ground terminal on the power source to the ground terminal on the device. For more
information, refer to
16
Section 2.5, "Grounding the
1
2
3
Section 2.5, "Grounding the
Device".
RUGGEDCOM MX5000
Installation Guide
Device".
Connecting DC Power